HPE Synergy Fabrics best practices

  • Install Ethernet/Converged fabric in Fabric 3 (ICM bays 3 and 6).

  • Install SAS storage fabric in Fabric 1 (ICM bays 1 and 4).

  • To use Fabric 2 (ICM bays 2 and 5) as a second Ethernet fabric or FC/SAS storage fabric, install two of either Ethernet or FC/SAS storage fabrics.

  • For Fabric 1, SAS storage ICMs take precedence over FC storage interconnect modules.

  • Populate both respective ICM bays for each fabric in support of module redundancy.

  • Both ICM bays within a fabric must contain the same interconnect modules unless the fabric is an HPE Synergy Composable Fabric.

  • For HPE Synergy Composable Fabrics, the frame can be populated with combinations of master and satellite modules, depending on the intended multiframe configuration.