Four frame cabling for HPE Virtual Connect SE 100Gb F32 Module for HPE Synergy modules (redundant)

This cabling example shows a redundant four frame configuration. In this configuration, frames 2 and 4 are cabled for 25Gb and frame 3 is cabled for 50Gb.

Prerequisites
HPE Synergy master and satellite interconnect module cabling (nonredundant)
Item Description Amount
1 HPE Virtual Connect SE 100Gb F32 Module for HPE Synergy

(primary master ICM)

1
2 HPE Virtual Connect SE 100Gb F32 Module for HPE Synergy

(secondary master ICM)

1
3 HPE Synergy 50Gb Interconnect Link Module

(primary satellite ICM)

3
4 HPE Synergy 50Gb Interconnect Link Module

(secondary satellite ICM)

3
Procedure
  1. Using interconnect link cables, connect the master ICM in ICM bay 3 to the satellite ICMs installed in ICM bay 3.
    1. Connect ports L1 of the master ICM to ports L1 of the satellite ICM in the same frame as the secondary master ICM.
    2. Connect port L2 of the master ICM to port L1 of the satellite ICM frame 4 ICM bay 3.
    3. Connect port L3 of the master ICM to port L1 of the satellite ICM frame 3 ICM bay 3.
    Figure 92: Master and satellite interconnect modules for four frames - primary master ICM cablingHPE Synergy master and satellite interconnect module cabling (nonredundant)

  2. Using interconnect link cables, connect the master ICM in ICM bay 6 to each satellite ICM installed in ICM bay 6.
    1. Connect port L1 from the secondary master ICM to port L1 on the satellite ICM in the same frame as the primary master ICM (frame 1).
    2. Connect port L2 from the secondary master ICM to port L1 on the satellite ICM in frame 4 ICM bay 6.
    3. Connect port L3 from the secondary master ICM to port L1 in the satellite ICM in frame 3 ICM bay 6.
    Figure 93: Master and satellite interconnect modules for four frames - secondary master ICM cablingHPE Synergy master and satellite interconnect module cabling (nonredundant)

  1. Cable two stacking cables from the master ICM in ICM bay 3 to the master ICM in ICM bay 6.
    1. Connect a stacking cable from port Q7 on the first master ICM to port Q7 on the second master ICM.
    2. Connect a stacking cable from port Q8 on the first master ICM to port Q8 on the second master ICM.
    Figure 94: Four frames with Master and satellite interconnect - stacking cablesHPE Synergy master and satellite interconnect module cabling (nonredundant)

  2. Cabling is complete.
    Figure 95: Four frames with Master and satellite interconnects (redundant) - all cablesHPE Synergy master and satellite interconnect module cabling (nonredundant)