Five frame cabling for HPE Virtual Connect SE 100Gb F32 Module for HPE Synergy modules (redundant)

This cabling example shows a redundant five frame configuration.

Prerequisites
HPE Synergy master and satellite interconnect module cabling (nonredundant)
Item Description Amount
1 HPE Virtual Connect SE 100Gb F32 Module for HPE Synergy

(primary master ICM)

1
2 HPE Virtual Connect SE 100Gb F32 Module for HPE Synergy

(secondary master ICM)

1
3 HPE Synergy 50Gb Interconnect Link Module

(satellite ICM)

8
Procedure
  1. Using interconnect link cables, connect the primary master switch ports to each satellite ICM in the same bay.
    1. Connect port L1 from the primary master ICM to port L1 on the satellite interconnect in the same frame as the secondary master ICM.
    2. Connect ports L2, L3, and L4 from the primary master ICM to port L1 in each of the remaining satellite ICM in ICM 3.
    Figure 96: Primary master and satellite interconnect module cabling for five frames (redundant)HPE Synergy master and satellite interconnect module cabling (nonredundant)

  2. Using interconnect link cables, connect the primary master switch ports to each satellite ICM in the same bay.
    1. Connect port L1 from the secondary master ICM to port L1 on the satellite interconnect in the same frame as the primary master ICM.
    2. Connect ports L2, L3, and L4 from the secondary master ICM to port L1 in each of the remaining satellite ICM in ICM 6.
    Figure 97: Secondary master and satellite interconnect module cabling for five frames (redundant)HPE Synergy master and satellite interconnect module cabling (nonredundant)
  3. Cable two stacking cables from the primary master ICM to the secondary master ICM.
    1. Connect a stacking cable from port Q7 on the first master ICM to port Q7 on the second master ICM.
    2. Connect a stacking cable from port Q8 on the first master ICM to port Q8 on the second master ICM.
    Figure 98: Master and satellite interconnect modules in multiple frames (redundant)HPE Synergy master and satellite interconnect module cabling (nonredundant)
  4. Cabling is complete.
    Figure 99: Master and satellite interconnect modules in five frames (redundant)HPE Synergy master and satellite interconnect module cabling (nonredundant)