Front USB module

CAUTION: To prevent damage to electrical components, take the appropriate anti-static precautions before beginning any installation, removal, or replacement procedure. Improper grounding can cause electrostatic discharge.
  1. Power down the server.
  2. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  3. Remove the access panel.
  4. Remove all USB devices from the front panel.
  5. Remove the tower bezel.
  6. Place the server on its side.
  7. If drives are installed in the drive cage, remove the drive cage.
  8. Disconnect the front USB module cable from the system board.


    Disconnecting the front USB module cable from the system board

  9. Remove the front USB module:
    1. Remove one screw on the module from the front panel.
    2. Move the module down and pull the cable out from the chassis.


      Removing the front USB module

To replace the components, reverse the removal procedure.