This features provides the ability to view diagnostic monitoring information for transceivers with Diagnostic Optical Monitoring (DOM) support. The following transceivers are supported:
Product # | Description |
---|---|
J8436A | 10GbE X2–SC SR Optic |
J8437A | 10GbE X2–SC LR Optic |
J4858A | Gigabit-SX-LC Mini-GBIC |
J4858B | Gigabit-SX-LC Mini-GBIC |
J4858C[*] | Gigabit-SX-LC Mini-GBIC |
[*] The J4858C transceivers with the letters “VM” in their serial numbers do not support DOM. |
Syntax:
Displays information about the transceivers. If a port is specified, displays information for the transceiver in that port.
Output for a specified transceiver
The output for show interfaces transceiver
is shown below. You can specify multiple ports, separated by commas, and the information for each transceiver displays.<port-list>
HP Switch(config)# show interfaces transceiver 21 Transceiver Technical information: Product Serial Part Port Type Number Number Number ------- ----------- ------------ ------------------ ---------- 21 1000SX J4858C MY050VM9WB 1990-3657
Output when no transceiver is present in specified interface
If there is no transceiver in the port specified in the command, the output displays as shown below.
HP Switch(config)# show interfaces transceiver 22 No Transceiver found on interface 22
Output when no ports are specified
When no ports are specified, information for all transceivers found is displayed.
HP Switch(config)# show interfaces transceiver Transceiver Technical information: Product Serial Part Port Type Number Number Number ------- ----------- ------------ ------------------ ---------- 21 1000SX J4858C MY050VM9WB 1990-3657 22 1000SX J4858B P834DIP2
Output when “all” is specified
You can specify all for <port-list>
as shown below.
HP Switch(config)# show interfaces transceiver all No Transceiver found on interface 1 No Transceiver found on interface 2 . . . No Transceiver found on interface 24 Transceiver Technical information: Product Serial Part Port Type Number Number Number ------- ----------- ------------ ------------------ ---------- 21 1000SX J4858C MY050VM9WB 1990-3657 22 1000SX J4858B P834DIP2
Transceiver information displayed with the detail parameter
When the show interfaces transceiver
command is executed, the following information displays.<port-list>
detail
General transceiver information
Parameter | Description | ||||||
---|---|---|---|---|---|---|---|
Interface Index | The switch interface number | ||||||
Transceiver-type | Pluggable transceiver type | ||||||
Transceiver model | Pluggable transceiver model | ||||||
Connector-type | Type of connector of the transceiver | ||||||
Wavelength | For an optical transceiver: the central wavelength of the laser sent, in nm. If the transceiver supports multiple wavelengths, the values are separated by a comma. | ||||||
Transfer Distance | Link-length supported by the transceiver in meters. The corresponding transfer medium is shown in brackets following the transfer distance value, for example, 50um multimode fiber. If the transceiver supports multiple transfer media, the values are separated by a comma. | ||||||
Diagnostic Support | Shows whether the transceiver supports diagnostics:
|
||||||
Serial Number | Serial number of the transceiver |
The information in DOM information, Alarm and error information (GBIC/SFP transceivers only), and Alarm and error information (XENPAK transceivers) is only displayed when the transceiver supports DOM.
DOM information
Parameter | Description |
---|---|
Temperature | Transceiver temperature (in degrees Centigrade) |
Voltage | Supply voltage in transceiver (Volts) |
Bias | Laser bias current (mA) |
RX power | Rx power (mW and dBm)) |
TX power | Tx power (mW and dBm) |
The alarm information for GBIC/SFP transceivers is shown in Alarm and error information (GBIC/SFP transceivers only).
Alarm and error information (GBIC/SFP transceivers only)
Alarm | Description |
---|---|
RX loss of signal | Incoming (RX) signal is lost |
RX power high | Incoming (RX) power level is high |
RX power low | Incoming (RX) power level is low |
TX fault | Transmit (TX) fault |
TX bias high | TX bias current is high |
TX bias low | TX bias current is low |
TX power high | TX power is high |
TX power low | TX power is low |
Temp high | Temperature is high |
Temp low | Temperature is low |
Voltage High | Voltage is high |
Voltage Low | Voltage is low |
The alarm information for XENPAK transceivers is shown in Alarm and error information (XENPAK transceivers).
Alarm and error information (XENPAK transceivers)
Alarm | Description |
---|---|
WIS local fault | WAN Interface Sublayer local fault |
Receive optical power fault | Receive optical power fault |
PMA/PMD receiver local fault | Physical Medium Attachment/Physical Medium Dependent receiver local fault |
PCS receiver local fault | Physical Coding Sublayer receiver local fault |
PHY XS receive local fault | PHY Extended Sublayer receive local fault |
RX power high | RX power is high |
RX power low | RX power is low |
Laser bias current fault | Laser bias current fault |
Laser temperature fault | Laser temperature fault |
Laser output power fault | Laser output power fault |
TX fault | TX fault |
PMA/PMD transmitter local fault | PMA/PMD transmitter local fault |
PCS Transmit local fault | PCS transmit local fault |
PHY XS transmit local fault | PHY SX transmit local fault |
TX bias high | TX bias current is high |
TX bias low | TX bias current is low |
TX power high | TX power is high |
TX power low | TX power is low |
Temp high | Temperature is high |
Temp low | Temperature is low |
Detailed information for a 1000SX Mini-GBIC transceiver
An example of the output for the show interfaces transceiver <port-list>
detail for a 1000SX transceiver is shown below.
HP Switch(config)# show interfaces transceiver 21 detail Transceiver in 21 Interface index : 21 Type : 1000SX Model : J4858C Connector type : LC Wavelength : 850nm Transfer distance : 300m (50um), 150m (62.5um), Diagnostic support : DOM Serial number : MY050VM9WB Status Temperature : 50.111C Voltage : 3.1234V TX Bias : 6mA TX Power : 0.2650mW, -5.768dBm RX Power : 0.3892mW, -4.098dBm Time stamp : Mon Mar 7 14:22:13 2011
Example of detailed information for a 10GbE-LR transceiver
An example of the output for a 10GbE-LR transceiver is shown below.
HP Switch(config)# show interfaces transceiver 23 detail Transceiver in 23 Interface Index : 24 Type : 10GbE-LR Model : J8437A Connector type : SC Wavelength : Channel #0: 1310nm, #1:0nm, #2:0nm, #3:0nm Transfer distance : 10000m (SM) Diagnostic support: DOM Serial number : ED456SS987 Status Temperature : 32.754C TX Bias : 42.700mA TX Power : 0.5192mW, -2.847dBm RX Power : 0.0040mW, -23.979dBm Recent Alarms: Rx power low alarm Rx power low warning Recent errors: Receive optical power fault PMA/PMD receiver local fault PMA/PMD transmitter local fault PCS receive local fault PHY XS transmit local fault Time stamp : Mon Mar 7 16:26:06 2011
|
|
NOTE: The hpicfTransceiver MIB is available for displaying transceiver information. |
|
|
Enter the test cable-diagnostics
command in any context to begin cable diagnostics for the transceiver. The diagnostic attempts to identify cable faults. The tests may take a few seconds to complete for each interface. There is the potential of link loss during the diagnostic.
Syntax:
Invokes cable diagnostics and displays the results.
Example of output from test cable-diagnostics command
HP Switch # test cable-diagnostics a23-a24 The ‘test cable-diagnostics’ command will cause a loss of link and will take a few seconds per interface to complete. Continue (Y/N)? y MDI Cable Distance Pair Pair MDI Port Pair Status to Fault Skew Polarity Mode ----- ----- ---------- --------- ----- --------- ------ A23 1-2 OK 0 m 6 ns Normal MDIX 3-6 OK 0 m 0 ns Normal 4-5 OK 0 m 6 ns Normal MDIX 7-8 OK 0 m 6 ns Normal A24 1-2 Short 2 m 3-6 Impedance 3 m 4-5 Impedance 3 m 7-8 Open 1 m
Example of copper cable diagnostic test results
HP Switch# show interfaces transceiver a23 detail Transceiver in A23 Interface Index : 23 Type : 1000T-sfp Model : J8177C Connector Type : RJ45 Wavelength : n/a Transfer Distance : 100m (copper), Diagnostic Support : VCT Serial Number : US051HF099 Link Status : Up Speed : 1000 Duplex : Full MDI Cable Distance Pair Pair MDI Port Pair Status to Fault Skew Polarity Mode ----- ----- ---------- --------- ----- --------- ----- A23 1-2 OK 0 m 6 ns Normal MDIX 3-6 OK 0 m 0 ns Normal 4-5 OK 0 m 6 ns Normal MDIX 7-8 OK 0 m 6 ns Normal Test Last Run : Fri Apr 22 20:33:23 2011
General transceiver information
Parameter | Description | ||||||
---|---|---|---|---|---|---|---|
Interface Index | The switch interface number | ||||||
Transceiver-type | Pluggable transceiver type | ||||||
Transceiver model | Pluggable transceiver model | ||||||
Connector-type | Type of connector of the transceiver | ||||||
Wavelength | For an optical transceiver: the central wavelength of the laser sent, in nm. If the transceiver supports multiple wavelengths, the values will be separated by a comma. An electrical transceiver value is displayed as N/A. | ||||||
Transfer Distance | Link-length supported by the transceiver in meters. The corresponding transfer medium is shown in brackets following the transfer distance value, for example, 50um multimode fiber. If the transceiver supports multiple transfer media, the values are separated by a comma. | ||||||
Diagnostic Support | Shows whether the transceiver supports diagnostics:
|
||||||
Serial Number | Serial number of the transceiver | ||||||
Link Status | Link up or down | ||||||
Speed | Speed of transceiver in Mbps | ||||||
Duplex | Type of duplexing | ||||||
Cable Status | Values are OK, Open, Short, or Impedance | ||||||
Distance to Fault | The distance in meters to a cable fault (accuracy is +/- 2 meters); displays 0 (zero) if there is no fault | ||||||
Pair Skew | Difference in propagation between the fastest and slowest wire pairs | ||||||
Pair Polarity | Signals on a wire pair are polarized, with one wire carrying the positive signal and one carrying the negative signal. | ||||||
MDI Mode | The MDI crossover status of the two wire pairs (1&2, 3&6, 4&5, 7&8), will be either MDI or MDIX |