bfd multi-hop detect-multiplier
Use bfd multi-hop detect-multiplier to set the multihop detection time multiplier.
Use undo bfd multi-hop detect-multiplier to restore the default.
Syntax
bfd multi-hop detect-multiplier value
undo bfd multi-hop detect-multiplier
Default
The multihop detection time multiplier is 5.
Views
System view
Predefined user roles
network-admin
Parameters
value: Specifies the multihop detection time multiplier in the range of 3 to 50.
Usage guidelines
The detection time multiplier determines the maximum number of concurrent BFD control packets that can be discarded.
Table 46: Detection interval calculation method
Mode | Detection interval |
---|---|
Control packet mode BFD session in asynchronous mode | Detection time multiplier of the receiver × actual packet sending interval of the receiver |
Control packet mode BFD session in demand mode | Detection time multiplier of the sender × actual packet sending interval of the sender |
Examples
# Set the multihop detection time multiplier to 6.
<Sysname> system-view [Sysname] bfd multi-hop detect-multiplier 6