display lldp neighbor-information
Use display lldp neighbor-information to display the LLDP information carried in LLDP TLVs that the local device receives from the neighboring devices.
Syntax
display lldp neighbor-information [ [ [ interface interface-type interface-number ] [ agent { nearest-bridge | nearest-customer | nearest-nontpmr } ] [ verbose ] ] | list [ system-name system-name ] ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
interface interface-type interface-number: Specifies a port by its type and number. If this option is not specified, this command displays the LLDP information that all ports receive from the neighboring devices.
agent: Specifies an agent by its type and number. If no agent type is specified, the command displays the LLDP information that all LLDP agents receive from the neighboring devices.
nearest-bridge: Specifies nearest bridge agents.
nearest-customer: Specifies nearest customer bridge agents.
nearest-nontpmr: Specifies nearest non-TPMR bridge agents.
verbose: Displays the detailed LLDP information that the local device receives from the neighboring devices. If this keyword is not specified, this command displays the brief LLDP information that the local device receives from the neighboring devices.
list: Displays the LLDP information that the local device receives from the neighboring devices in the form of a list.
system-name system-name: Displays the LLDP information that the local device receives from a neighboring device specified by its system name. The system-name argument is a string of 1 to 255 characters. If this option is not specified, this command displays the LLDP information that the local device receives from all neighboring devices in a list.
Examples
# Display the detailed LLDP information that the nearest bridge agents on all ports received from the neighboring devices. (DCBX is IEEE Std 802.1Qaz-2011.)
<Sysname> display lldp neighbor-information agent nearest-bridge verbose LLDP neighbor-information of port 1[Ten-GigabitEthernet1/0/1]: LLDP agent nearest-bridge: LLDP Neighbor index : 1 Update time : 0 days, 0 hours, 1 minutes, 1 seconds Chassis type : MAC address Chassis ID : 000f-0055-0002 Port ID type : Interface name Port ID : Ten-GigabitEthernet1/0/1 Time to live : 120 Port description : Ten-GigabitEthernet1/0/1 Interface System name : Sysname System description : HPE Comware Platform Software System capabilities supported : Bridge, Router, Customer Bridge, Service Bridge System capabilities enabled : Bridge, Router, Customer Bridge Management address type : IPv4 Management address : 192.168.1.55 Management address interface type : IfIndex Management address interface ID : Unknown Management address OID : 0 DCBX Control info: Oper version : Standard DCBX ETS configuration info: CBS : False Max TCs : 8 CoS Local priority Percentage TSA 0 0 15 ETS 1 1 0 SP 2 2 15 ETS 3 3 14 ETS 4 4 14 ETS 5 5 14 ETS 6 6 14 ETS 7 7 14 ETS DCBX ETS recommendation info: CoS Local priority Percentage TSA 0 0 15 ETS 1 1 0 SP 2 2 15 ETS 3 3 14 ETS 4 4 14 ETS 5 5 14 ETS 6 6 14 ETS 7 7 14 ETS DCBX PFC info: P0-0 P1-1 P2-1 P3-1 P4-0 P5-0 P6-0 P7-0 Number of traffic classes supported: 8 Value of MBC: 0 DCBX APP info: Selected Field Protocol ID Priority UDP/DCCP 100 0x3 TCP/SCTP 200 0x3 Ethertype 0x1234 0x3 Ethertype 0x8906 0x3 Port VLAN ID(PVID): 1 Port and protocol VLAN ID(PPVID) : 0 Port and protocol VLAN supported : No Port and protocol VLAN enabled : No VLAN name of VLAN 12: VLAN 0012 Management VLAN ID : 5 Auto-negotiation supported : Yes Auto-negotiation enabled : Yes OperMau : Speed(1000)/Duplex(Full) Power port class : PD PSE power supported : Yes PSE power enabled : Yes PSE pairs control ability : Yes Power pairs : Signal Port power classification : Class 0 Link aggregation supported : Yes Link aggregation enabled : Yes Aggregation port ID : 52 Maximum frame size : 1500
# Display the detailed LLDP information that all LLDP agents on all ports received from the neighboring devices. (DCBX is IEEE Std 802.1Qaz-2011.)
<Sysname> display lldp neighbor-information verbose LLDP neighbor-information of port 1[Ten-GigabitEthernet1/0/1]: LLDP agent nearest-bridge: LLDP Neighbor index : 1 Update time : 0 days, 0 hours, 1 minutes, 1 seconds Chassis type : MAC address Chassis ID : 000f-0055-0002 Port ID type : Interface name Port ID : Ten-GigabitEthernet1/0/1 Time to live : 121 Port description : Ten-GigabitEthernet1/0/1 Interface System name : Sysname System description : HPE Comware Platform Software System capabilities supported : Bridge, Router, Customer Bridge, Service Bridge System capabilities enabled : Bridge, Router, Customer Bridge Management address type : IPv4 Management address : 192.168.1.55 Management address interface type : IfIndex Management address interface ID : Unknown Management address OID : 0 DCBX control info: Oper version : Standard DCBX ETS configuration info: CBS : False Max TCs : 8 CoS Local Priority Percentage TSA 0 0 15 ETS 1 1 0 SP 2 2 15 ETS 3 3 14 ETS 4 4 14 ETS 5 5 14 ETS 6 6 14 ETS 7 7 14 ETS DCBX ETS recommendation info: CoS Local Priority Percentage TSA 0 0 15 ETS 1 1 0 SP 2 2 15 ETS 3 3 14 ETS 4 4 14 ETS 5 5 14 ETS 6 6 14 ETS 7 7 14 ETS DCBX PFC info: P0-0 P1-1 P2-1 P3-1 P4-0 P5-0 P6-0 P7-0 Number of traffic classes supported: 8 Value of MBC: 0 DCBX APP info: Selected Field Protocol ID Priority UDP/DCCP 100 0x3 TCP/SCTP 200 0x3 Ethertype 0x1234 0x3 Ethertype 0x8906 0x3 Port VLAN ID(PVID): 1 Port and protocol VLAN ID(PPVID) : 0 Port and protocol VLAN supported : No Port and protocol VLAN enabled : No VLAN name of VLAN 12: VLAN 0012 Management VLAN ID : 5 Auto-negotiation supported : Yes Auto-negotiation enabled : Yes OperMau : Speed(1000)/Duplex(Full) Power port class : PD PSE power supported : Yes PSE power enabled : Yes PSE pairs control ability : Yes Power pairs : Signal Port power classification : Class 0 Link aggregation supported : Yes Link aggregation enabled : Yes Aggregation port ID : 52 Maximum frame size : 1500 LLDP neighbor-information of port 1[Ten-GigabitEthernet1/0/1]: LLDP agent nearest-nontpmr: LLDP Neighbor index : 1 Update time : 0 days, 0 hours, 1 minutes, 1 seconds Chassis type : MAC address Chassis ID : 000f-0055-0002 Port ID type : Interface name Port ID : Ten-GigabitEthernet1/0/1 Time to live : 121 Port description : Ten-GigabitEthernet1/0/1 Interface System name : Sysname System description : HPE Comware Platform Software System capabilities supported : Bridge, Router, Customer Bridge, Service Bridge System capabilities enabled : Bridge, Router, Customer Bridge Management address type : IPv4 Management address : 192.168.1.55 Management address interface type : IfIndex Management address interface ID : Unknown Management address OID : 0 Port VLAN ID(PVID): 1 Port and protocol VLAN ID(PPVID) : 12 Port and protocol VLAN supported : Yes Port and protocol VLAN enabled : Yes VLAN name of VLAN 12: VLAN 0012 Auto-negotiation supported : Yes Auto-negotiation enabled : Yes OperMau : Speed(1000)/Duplex(Full) Power port class : PD PSE power supported : Yes PSE power enabled : Yes PSE pairs control ability : Yes Power pairs : Signal Port power classification : Class 0 Link aggregation supported : Yes Link aggregation enabled : Yes Aggregation port ID : 52 Maximum frame size : 1500
# Display the brief LLDP information that all LLDP agents on all ports received from the neighboring devices.
<Sysname> display lldp neighbor-information LLDP neighbor-information of port 52[Ten-GigabitEthernet1/0/3]: LLDP agent nearest-bridge: LLDP neighbor index : 3 ChassisID/subtype : 0011-2233-4400/MAC address PortID/subtype : 000c-29f5-c71f/MAC address Capabilities : Bridge, Router, Customer Bridge LLDP neighbor index : 6 ChassisID/subtype : 0011-2233-4400/MAC address PortID/subtype : 000c-29f5-c715/MAC address Capabilities : None CDP neighbor-information of port 52[Ten-GigabitEthernet1/0/3]: LLDP agent nearest-bridge: CDP neighbor index : 4 Chassis ID : SEP00260B5C0548 Port ID : Port 1 CDP neighbor index : 5 Chassis ID : 0011-2233-4400 Port ID : Ten-GigabitEthernet1/0/4 LLDP neighbor-information of port 52[Ten-GigabitEthernet1/0/3]: LLDP agent nearest-nontpmr: LLDP neighbor index : 6 ChassisID/subtype : 0011-2233-4400/MAC address PortID/subtype : 000c-29f5-c715/MAC address Capabilities : None
# Display the brief LLDP information that all LLDP agents received from all neighboring devices in a list.
<Sysname> display lldp neighbor-information list Chassis ID : * -- --Nearest nontpmr bridge neighbor # -- --Nearest customer bridge neighbor Default -- -- Nearest bridge neighbor System Name Local Interface Chassis ID Port ID System1 XGE1/0/1 000f-e25d-ee91 Ten-GigabitEthernet1/0/5 System2 XGE1/0/2 000f-e25d-ee92* Ten-GigabitEthernet1/0/6 System3 XGE1/0/3 000f-e25d-ee93# Ten-GigabitEthernet1/0/7
Table 60: Command output
Field | Description |
---|---|
LLDP neighbor-information of port 1 | LLDP information received through port 1. |
Update time | Time when LLDP information about a neighboring device was last updated. |
Chassis type | Chassis ID type:
|
Chassis ID | ID that identifies the LLDP sending device, which can be a MAC address, a network address, an interface, or some other value, depending on the chassis type of the neighboring device. |
Port ID type | Port ID type:
|
Port ID | Value of the type of the port ID. |
System name | System name of the neighboring device. |
System description | System description of the neighboring device. |
System capabilities supported | Capabilities supported on the neighboring device:
|
System capabilities enabled | Capabilities enabled on the neighboring device:
|
Management address OID | Management address object ID. |
DCBX control info | Displayed as version information in IEEE Std 802.1Qaz-2011. |
Oper version | DCBX version number. |
Sequence number | Number of DCBX TLV content changes. |
Acknowledge number | Times of synchronizing configurations by the peer device. |
DCBX ETS info | CoS-to-local priority mapping and bandwidth allocation. |
Percentage | Percentage of bandwidth allocated. |
P0- P1- P2- P3- P4- P5- P6- P7- | Number of supported priorities configured by using the priority-flow-control no-drop dot1p dot1p-list command on the neighbor. |
Number of traffic classes supported | Capability set supported by PFC (displayed only in Rev 1.01 and IEEE Std 802.1Qaz-2011). |
CoS map | Application protocol-to-CoS mapping. |
CBS | Indicates whether the token bucket mechanism is supported on the port:
|
Max TCs | Maximum number of priorities supported. |
TSA | Transmission selection algorithm. |
Value of MBC | MBC indicates the ability of packets to bypass MACsec. It is 1-bit long.
|
Port and protocol VLAN ID(PPVID) | Port protocol VLAN ID. |
Port and protocol VLAN supported | Indicates whether protocol VLAN is supported on the port. |
Port and protocol VLAN enabled | Indicates whether protocol VLAN is enabled on the port. |
VLAN name of VLAN 12 | Name of VLAN 12. |
Auto-negotiation supported | Indicates whether autonegotiation is supported on the port. |
Auto-negotiation enabled | Indicates whether autonegotiation is enabled on the port. |
OperMau | Speed and duplex state on the port. |
Power port class | PoE port class:
|
PSE power supported | Indicates whether the device can operate as a PSE. |
PSE power enabled | Indicates whether the device is operating as a PSE. |
PSE pairs control ability | Indicates whether the pair selection ability is available. |
Power pairs | Power supply mode:
|
Port power classification | Power class of the PD:
|
Link aggregation supported | Indicates whether link aggregation is supported. |
Link aggregation enabled | Indicates whether link aggregation is enabled. |
TLV type | Unknown basic TLV type. |
TLV information | Information contained in the unknown basic TLV type. |
Unknown organizationally-defined TLV | Unknown organizationally specific TLV. |
TLV OUI | OUI of the unknown organizationally specific TLV. |
TLV subtype | Unknown organizationally specific TLV subtype. |
Index | Unknown organization index. |
Capabilities | Capabilities enabled on the neighboring device:
|
Local Interface | Local port that receives the LLDP information. |
Chassis ID : * -- -- Nearest nontpmr bridge neighbor #-- -- Nearest customer bridge neighbor | Chassis ID flag:
|