IS-IS PDUs

PDU

IS-IS PDUs are encapsulated into link layer frames. An IS-IS PDU has two parts, the headers and the variable length fields. The headers comprise the PDU common header and the PDU specific header. All PDUs have the same PDU common header. The specific headers vary by PDU type.

Figure 37: PDU format

Table 11: PDU types

Type

PDU Type

Acronym

15

Level-1 LAN IS-IS hello PDU

L1 LAN IIH

16

Level-2 LAN IS-IS hello PDU

L2 LAN IIH

17

Point-to-Point IS-IS hello PDU

P2P IIH

18

Level-1 Link State PDU

L1 LSP

20

Level-2 Link State PDU

L2 LSP

24

Level-1 Complete Sequence Numbers PDU

L1 CSNP

25

Level-2 Complete Sequence Numbers PDU

L2 CSNP

26

Level-1 Partial Sequence Numbers PDU

L1 PSNP

27

Level-2 Partial Sequence Numbers PDU

L2 PSNP

Hello PDU

IS-to-IS hello (IIH) PDUs are used by routers to establish and maintain neighbor relationships. On broadcast networks, Level-1 routers use Level-1 LAN IIHs, and Level-2 routers use Level-2 LAN IIHs. The P2P IIHs are used on point-to-point networks.

LSP

The LSPs carry link state information. LSPs include Level-1 LSPs and Level-2 LSPs. The Level-2 LSPs are sent by the Level-2 routers, and the Level-1 LSPs are sent by the Level-1 routers. The Level-1-2 router can send both types of LSPs.

SNP

A sequence number PDU (SNP) describes the complete or partial LSPs for LSDB synchronization.

SNPs include CSNP and PSNP, which are further divided into Level-1 CSNP, Level-2 CSNP, Level-1 PSNP, and Level-2 PSNP.

A CSNP describes the summary of all LSPs for LSDB synchronization between neighboring routers. On broadcast networks, CSNPs are sent by the DIS periodically (every 10 seconds by default). On point-to-point networks, CSNPs are sent only during the first adjacency establishment.

A PSNP only contains the sequence numbers of one or multiple latest received LSPs. It can acknowledge multiple LSPs at one time. When LSDBs are not synchronized, a PSNP is used to request missing LSPs from a neighbor.

CLV

The variable fields of PDU comprise multiple Code-Length-Value (CLV) triplets.

Figure 38: CLV format

Table 12 shows that different PDUs contain different CLVs. Codes 1 through 10 are defined in ISO 10589 (code 3 and 5 are not shown in the table), and others are defined in RFC 1195.

Table 12: CLV codes and PDU types

CLV Code

Name

PDU Type

1

Area Addresses

IIH, LSP

2

IS Neighbors (LSP)

LSP

4

Partition Designated Level 2 IS

L2 LSP

6

IS Neighbors (MAC Address)

LAN IIH

7

IS Neighbors (SNPA Address)

LAN IIH

8

Padding

IIH

9

LSP Entries

SNP

10

Authentication Information

IIH, LSP, SNP

128

IP Internal Reachability Information

LSP

129

Protocols Supported

IIH, LSP

130

IP External Reachability Information

L2 LSP

131

Inter-Domain Routing Protocol Information

L2 LSP

132

IP Interface Address

IIH, LSP