Connecting the power cord


[CAUTION: ]

CAUTION:

  • Provide a circuit breaker for each power cord.

  • Before connecting the power cord, make sure the circuit breaker on the power cord is turned off.


Table 5: Power cord connection procedures at a glance

Switch model

Available power source

Connection procedure reference

  • HPE 5130 24G 4SFP+ EI

  • HPE 5130 24G 2SFP+ 2XGT EI

  • HPE 5130 24G 4SFP+ EI BR

AC power source

Connecting the switch to an AC power source

  • HPE 5130 48G 4SFP+ EI

  • HPE 5130 24G SFP 4SFP+ EI

  • HPE 5130 48G 2SFP+ 2XGT EI

  • HPE 5130 48G 4SFP+ EI BR

AC power source

Connecting the switch to an AC power source

–48 V DC power source in the equipment room

Connecting the switch to a –48 VDC power source

RPSRecommended HPE RPS models: A-RPS800 (JD183A ) and A-RPS1600 (JG136A)

Connecting the switch to an RPS

  • HPE 5130 24G PoE+ 4SFP+ (370W) EI

  • HPE 5130 48G PoE+ 4SFP+ (370W) EI

  • HPE 5130 24G PoE+ 2SFP+ 2XGT (370W) EI

  • HPE 5130 48G PoE+ 2SFP+ 2XGT (370W) EI

  • HPE 5130 24G PoE+ 4SFP+ (370W) EI BR

  • HPE 5130 48G PoE+ 4SFP+ (370W) EI BR

AC power source

Connecting the switch to an AC power source

HPE A-RPS1600

Connecting the switch to an RPS

The HPE 5130 24G SFP 4SFP+ EI switch provides two power supply slots. The PSR150-A/PSR150-A1 (JD362A/JD362B) and PSR150-D/PSR150-D1 (JD366A/JD366B) power supplies are available for the HPE 5130 24G SFP 4SFP+ EI switch. The PSR150-A/PSR150-A1 (JD362A/JD362B)power supply supports AC power input. The PSR150-D/PSR150-D1 (JD366A/JD366B) power supply supports –48 V DC power input and RPS power input.