bfd min-echo-receive-interval

Syntax

bfd min-echo-receive-interval value

undo bfd min-echo-receive-interval

View

Interface view

Default level

2: System level

Parameters

value: Minimum echo receiving interval, in milliseconds. The value must be a multiple of 100 and range from 200 to 1000.

Description

Use bfd min-echo-receive-interval to configure the minimum echo packet receiving interval on the interface.

Use undo bfd min-echo-receive-interval to restore the default minimum echo packet receiving interval on the interface.

By default, the minimum echo packet receiving interval is 400 milliseconds

Examples

# Configure the minimum echo receiving interval on VLAN-interface 1 as 500 milliseconds.

<Sysname> system-view
[Sysname] interface vlan-interface 1
[Sysname-Vlan-interface1] bfd min-echo-receive-interval 500