Associating Track with ERPS

About Track association with ERPS

To detect and clear link faults typically for a fiber link, use ERPS with CFD and Track. You can associate ERPS ring member ports with the continuity check function of CFD through track entries. CFD reports link events only when the monitored VLAN is the control VLAN of the ERPS instance for the port.

Track changes the track entry state based on the monitoring result of CFD, and notifies the track entry state change to the associated EPRS ring.

For more information about ERPS, see "Configuring ERPS."

Restrictions and guidelines

Before you associate a port with a track entry, make sure the port has joined an ERPS instance.

Procedure

  1. Enter system view.

    system-view

  2. Enter Layer 2 Ethernet interface view or Layer 2 aggregate interface view.

    interface interface-type interface-number

  3. Associate an ERPS ring member port with a track entry.

    port erps ring ring-id instance instance-id track track-entry-index

    By default, an ERPS ring member port is not associated with any track entries.