Associating Track with EAA

About Track association with EAA

You can configure EAA track event monitor policies to monitor the positive-to-negative or negative-to-positive state changes of track entries.

You can set a suppression time for a track event monitor policy. The timer starts when the policy is triggered. The system does not process messages that report the monitored track event until the timer times out.

For more information about EAA, see Network Management and Monitoring Configuration Guide.

Procedure

  1. Enter system view.

    system-view

  2. Create a CLI-defined monitor policy and enter its view, or enter the view of an existing CLI-defined monitor policy.

    rtm cli-policy policy-name

  3. Configure a track event.

    event track track-entry-number-list state { negative | positive } [ suppress-time suppress-time ]

    By default, a monitor policy does not monitor any track event.