Operation note
The advertisement of power with TLVs for LLDP
PoE+ is enabled by default. If LLDP is disabled at runtime and a PD
is using PoE+ power that has been negotiated through LLDP, there will
be a temporary power drop. The port will begin using PoE+ power through
the PLC. This event is recorded in the event log. An Example: message
would look like the following:
W 08/04/13 13:35:50 02768 ports: Port A1 PoE power dropped. Exceeded physical classification for a PoE Type1 device (LLDP process disabled)When LLDP is enabled again, it causes a temporary power drop. This event is also recorded in the event log. An Example: message looks like the following:
W 08/04/13 13:36:31 02771 ports: Port A1 PoE power dropped. Exceeded physical classification due to change in classification type (LLDP process enabled)