Troubleshooting an instance

To troubleshoot instances, check the following.

  • To connect a controller, there must be ip-connectivity between controller and switch over the controller VLAN.
  • The controller must be capable of negotiating to a version equal to or less than the configured or supported version

  • Use the show openflow command to check instances.

Example

switch(openflow)# show openflow
OpenFlow : Enabled
Egress Only Ports Mode : Disabled
Instance Information
No. of No. of OpenFlow
Instance Name Oper. Status H/W Flows S/W Flows Version
------------------------------ ------------ ---------- ---------- --------
test Up 1 4 1.0

Use the show openflow instance <instance-name> command.

Example

switch(openflow)# show openflow instance test
Configured OF Version : 1.0
Negotiated OF Version : 1.0
Instance Name : test
Data-path Description : test
Administrator Status : Enabled
Member List : VLAN 3
Pipeline Model : Standard MatchListen Port : 6633
Operational Status : Up
Operational Status Reason : NA
Datapath ID : 000340a8f09e8600
Mode : Active
Flow Location : Hardware and Software
No. of Hardware Flows : 1
No. of Software Flows : 4
Hardware Rate Limit : 0 kbps
Software Rate Limit : 100 pps
Conn. Interrupt Mode : Fail-Secure
Maximum Backoff Interval : 60 seconds
Probe Interval : 10 seconds
Hardware Table Miss Count : 0
No. of Software Flow Tables : NA
Egress Only Ports : None
Table Model : Single Table
Source MAC Group Table : Disabled
Destination MAC Group Table : Disabled
Controller Id Connection Status Connection State Secure Role
------------- ----------------- ---------------- ------ ------
1 Connected Active No Equal