Instance error messages
Enable a named instance
Attempting to enable a named instance without
a listen port or controller and a member VLAN displays an error message
similar to the following:
A controller and a member VLAN must be added
to the named instance before enabling it.
Enable an aggregate instance
Attempting to enable an aggregate instance without
a listen port or controller displays an error message similar to the
following:
A listen-port or a controller must be added
to the aggregate instance before enabling it.
Maximum number of instances
Configuring an instance when the maximum number
of OpenFlow instances is already configured displays an error message
similar to the following:
Maximum number of OpenFlow instances (128) already
configured.
Instance name that exceeds length
Configuring an instance with a name that exceeds
the maximum length requirement displays an error message similar to
the following:
Maximum length of the instance-name is 32 characters.
Create an aggregate instance
Trying to create an aggregate instance when a
named instance exists on the switch displays an error message similar
to the following:
An aggregate instance cannot be created when
named instances exist.
Create a named instance
Trying to create a named instance when an aggregate
instance is already configured displays an error message similar to
the following:
Named instances cannot be created when an aggregate
instance exists.
Deleting an instance
Trying to delete a nonexistent instance displays
an error message similar to the following:
Instance not found.
Enabling an instance
Attempting to enable an OpenFlow instance without
configuring a listen port or a controller displays an error message
similar to the following:
A listen-port or a controller, and a member
VLAN must be added to the named instance before enabling it.
Delete a member
Trying to delete a member that does not belong
to the instance displays an error message similar to the following:
VLAN VLAN-ID is not
a member of this instance.
Modifying backoff interval
Trying to modify the backoff interval when the
instance is enabled displays an error message similar to the following:
Instance configuration cannot be modified when
the instance is enabled.
Instance name
When naming an instance, only alphabetic characters,
numerals, and underscores are allowed in the instance name. Failure
to follow this rule results in an error message similar to the following:
Invalid name. Only alphanumeric characters and
underscores are allowed.