Additional commands affected by redundant management
The other existing commands operate with redundant management as shown below.
Command |
Action |
---|---|
auto-tftp |
If a new image is downloaded using |
banner |
The banner will not been seen on the standby module, only the active module. |
chassislocate |
If the management module performs a switchover, the LED does not remain lit. |
clear |
The |
console |
Console settings, such as mode, flow-control, and baud-rate, are the same on both management modules. There cannot be individual settings for each management module. |
copy |
Files are automatically sync'd from the active
management module to the standby management module.When
no parameter is specified with the
copy crash-data or copy crash-log command, files from all modules
(management and interface) are concatenated.NOTE:
If redundancy is disabled or the standby module failed selftest,
the |
|
The
copy core-dump standby flash command
copies the standby management module's coredump to the active
management module's flash. The destination file is fixed as dumpM1.cor
or dumpM2.cor, depending on which module is the standby management
module.The command copies the core file
of the active management module or the standby management module to
a USB flash drive or to an xmodem host.
|
core-dump management-module |
Enables or disables a core dump on a management module. |
crypto |
Authentication files for ssh or the https server are
copied to the standby management module. The |
erase flash |
Erases the software version on the active and standby modules. If redundancy has been disabled, or if the standby module has not passed selftest, the flash is not erased on the standby module. |
erase config |
Erases the config file on the active and standby modules. If redundancy has been disabled, or if the standby module has not passed selftest, the config file is not erased on the standby module. |
erase startup-config |
Affects both modules if the second module is in
standby mode. If redundancy has been disabled, or if the standby module
has not passed selftest, the |
fastboot |
When fastboot is enabled, this information is saved to the standby management module when the config files are sync'd. The fastboot value is used during the next boot on both modules. |
|
This command and its options affect only the active management module. |
kill |
Does not affect the console on the standby module. |
log |
Log messages from a formerly active management module are available on the current active management module after a switchover. |
password (set or |
Affects only the active management module until a switchover occurs, at which time it affects the new active module. |
startup-default |
Affects both modules. The config file is immediately sent to the standby module and also becomes the default on that module when the next boot occurs. |
update |
Affects only the active module. The standby may become the active module when the updated active module is booted. |
write |
A |