Printable version

Drivers & software

* RECOMMENDED * Firmware Flash Component for Windows - HPE MSA 1040/2040/1050/2050 8TB 12G SAS 7.2K rpm LFF Drive Model (HUH728080AL5204)

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - SAS Storage Disk
Version: CD05(2 Jul 2018)
Operating System(s): HP-UX 11.23
HP-UX 11.31 (IA)
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Microsoft Windows Server 2016
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
VMware ESXi 5.0
VMware vSphere 5.1
VMware vSphere 5.5
VMware vSphere 6.0
VMware vSphere 6.5
File name: cp034438.exe (6.7 MB)
This Windows Smart Component contains a firmware update for LFF hard drive model HUH728080AL5204 (8TB 12G SAS 7.2K) in HPE MSA 1040/2040/1050/2050 Storage Array.

The following enhancement was incorporated in this version:

  • Improved multiple sequential read performance

Prerequisites:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

IMPORTANT: Ensure that no other user is performing administrative functions on the HPE MSA 1040/2040/1050/2050 Storage Array.

NOTE: Disk drive upgrades on the HPE MSA 1040/2040/1050/2050 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HPE Modular Storage Array Reference Guides. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flash summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HPE MSA 1040/2040/1050/2050 Storage Array.

IMPORTANT: HTTPS or Telnet service must be enabled on the arrays being updated and the corresponding connection must not be blocked by any firewall on the host system where the smart component is being executed. The Smart Component will manage the SFTP/FTP settings and PFU settings (enabled or disabled) in the arrays during flashing.


To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

bbd6a36229829f9a33bf25a8b6cf2c2ed15f8066eb719903dd40c86cc8732489 cp034438.exe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Installation instructions using Smart Component:

The Smart Component package is a self-extracting executable. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI).

GUI option:

  1. Place the downloaded firmware package in a temporary directory.
  2. Using Windows Explorer, navigate to the directory containing the download.
  3. Double click the executable file.
  4. Follow onscreen instructions. After you are prompted for logon information, enter credentials for an account with management access rights.
  5. Wait for the installation to complete. Upon completion, a confirmation message is displayed.

CLI option:

  1. Place the downloaded firmware package in a temporary directory.
  2. Using Windows command prompt, navigate to the directory containing the download.
  3. Execute the Smart Component by entering the following command:        

    CPxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s
    where:
  •  ip_address is the management IP address of the array controller
  •  username is the username account with management rights
  •  password is the password for username

Instead of command line parameters you can use the following DOS environment variables:

  •  oa_address: set this variable for the IP address of array controller
  •  oa_username : set this variable for the username of array controller
  •  oa_password : set this variable for the password of that username.

Wait for the installation to complete. Upon completion, a confirmation message is displayed.

NOTE:

  • Stop all I/O to array before starting the firmware update.
  • When prompted for logon information, enter credentials for an account with management access rights.
  • For details on supported command options, see the online help by executing the command CPxxxxxx.exe /h or /?

End User License Agreements:
HPE Software License Agreement v1
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

IMPORTANT: Ensure that no other user is performing administrative functions on the HPE MSA 1040/2040/1050/2050 Storage Array.

NOTE: Disk drive upgrades on the HPE MSA 1040/2040/1050/2050 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HPE Modular Storage Array Reference Guides. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flash summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HPE MSA 1040/2040/1050/2050 Storage Array.

IMPORTANT: HTTPS or Telnet service must be enabled on the arrays being updated and the corresponding connection must not be blocked by any firewall on the host system where the smart component is being executed. The Smart Component will manage the SFTP/FTP settings and PFU settings (enabled or disabled) in the arrays during flashing.


Supported Devices and Features:

Firmware on the listed drives can be updated when attached to any of the following Storage Systems:         

  • HPE MSA 1040 SAN LFF Storage      
  • HPE MSA 1040 SAS LFF Storage
  • HPE MSA 2040 SAN LFF Storage    
  • HPE MSA 2040 SAS LFF Storage
  • HPE MSA 2042 SAN LFF Storage   
  • HPE MSA 2042 SAS LFF Storage   
  • HPE MSA 1050 SAN LFF Storage
  • HPE MSA 1050 SAS LFF Storage
  • HPE MSA 2050 SAN LFF Storage  
  • HPE MSA 2050 SAS LFF Storage
  • HPE MSA 2052 SAN LFF Storage  
  • HPE MSA 2052 SAS LFF Storage
  • HPE MSA 2040 LFF Disk Enclosure
  • HPE MSA 2050 LFF Disk Enclosure

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issues were fixed in this firmware:

  • Fixed an internal drive reset due to unaligned write handling
  • Fixed an internal drive reset during power on sequence
  • Fixed issues where the drive became unresponsive during READ operations

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

IMPORTANT: Ensure that no other user is performing administrative functions on the HPE MSA 1040/2040/1050/2050 Storage Array.

NOTE: Disk drive upgrades on the HPE MSA 1040/2040/1050/2050 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HPE Modular Storage Array Reference Guides. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flash summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HPE MSA 1040/2040/1050/2050 Storage Array.

IMPORTANT: HTTPS or Telnet service must be enabled on the arrays being updated and the corresponding connection must not be blocked by any firewall on the host system where the smart component is being executed. The Smart Component will manage the SFTP/FTP settings and PFU settings (enabled or disabled) in the arrays during flashing.

Version:CD05 (2 Jul 2018)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issues were fixed in this firmware:

  • Fixed an internal drive reset due to unaligned write handling
  • Fixed an internal drive reset during power on sequence
  • Fixed issues where the drive became unresponsive during READ operations
Enhancements

The following enhancement was incorporated in this version:

  • Improved multiple sequential read performance

Version:C907 (13 Oct 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issues were fixed in this release of firmware:

  • Multiple self-initiated resets
  • Issue in 512 byte emulation mode which led to resource exhaustion
  • Sync issue when drive is in idle
Enhancements

Following enhancements were added to this version of firmware:

  • Improved performance in various workloads
  • Improved servo track settling and power calibration

Version:C7J0 (7 Oct 2015)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Following issues are fixed in this firmware:

  • Issues with Self-Initiated resets
  • Command timeouts
  • 0B/44/00 error
  • Errors found during WRITE

Type: Firmware - SAS Storage Disk
Version: CD05(2 Jul 2018)
Operating System(s):
HP-UX 11.23
HP-UX 11.31 (IA)
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Microsoft Windows Server 2016
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
VMware ESXi 5.0
VMware vSphere 5.1
VMware vSphere 5.5
VMware vSphere 6.0
VMware vSphere 6.5

Description

This Windows Smart Component contains a firmware update for LFF hard drive model HUH728080AL5204 (8TB 12G SAS 7.2K) in HPE MSA 1040/2040/1050/2050 Storage Array.

Enhancements

The following enhancement was incorporated in this version:

  • Improved multiple sequential read performance

Installation Instructions

Prerequisites:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

IMPORTANT: Ensure that no other user is performing administrative functions on the HPE MSA 1040/2040/1050/2050 Storage Array.

NOTE: Disk drive upgrades on the HPE MSA 1040/2040/1050/2050 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HPE Modular Storage Array Reference Guides. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flash summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HPE MSA 1040/2040/1050/2050 Storage Array.

IMPORTANT: HTTPS or Telnet service must be enabled on the arrays being updated and the corresponding connection must not be blocked by any firewall on the host system where the smart component is being executed. The Smart Component will manage the SFTP/FTP settings and PFU settings (enabled or disabled) in the arrays during flashing.


To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

bbd6a36229829f9a33bf25a8b6cf2c2ed15f8066eb719903dd40c86cc8732489 cp034438.exe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Installation instructions using Smart Component:

The Smart Component package is a self-extracting executable. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI).

GUI option:

  1. Place the downloaded firmware package in a temporary directory.
  2. Using Windows Explorer, navigate to the directory containing the download.
  3. Double click the executable file.
  4. Follow onscreen instructions. After you are prompted for logon information, enter credentials for an account with management access rights.
  5. Wait for the installation to complete. Upon completion, a confirmation message is displayed.

CLI option:

  1. Place the downloaded firmware package in a temporary directory.
  2. Using Windows command prompt, navigate to the directory containing the download.
  3. Execute the Smart Component by entering the following command:        

    CPxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s
    where:
  •  ip_address is the management IP address of the array controller
  •  username is the username account with management rights
  •  password is the password for username

Instead of command line parameters you can use the following DOS environment variables:

  •  oa_address: set this variable for the IP address of array controller
  •  oa_username : set this variable for the username of array controller
  •  oa_password : set this variable for the password of that username.

Wait for the installation to complete. Upon completion, a confirmation message is displayed.

NOTE:

  • Stop all I/O to array before starting the firmware update.
  • When prompted for logon information, enter credentials for an account with management access rights.
  • For details on supported command options, see the online help by executing the command CPxxxxxx.exe /h or /?

Release Notes

End User License Agreements:
HPE Software License Agreement v1
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

IMPORTANT: Ensure that no other user is performing administrative functions on the HPE MSA 1040/2040/1050/2050 Storage Array.

NOTE: Disk drive upgrades on the HPE MSA 1040/2040/1050/2050 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HPE Modular Storage Array Reference Guides. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flash summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HPE MSA 1040/2040/1050/2050 Storage Array.

IMPORTANT: HTTPS or Telnet service must be enabled on the arrays being updated and the corresponding connection must not be blocked by any firewall on the host system where the smart component is being executed. The Smart Component will manage the SFTP/FTP settings and PFU settings (enabled or disabled) in the arrays during flashing.


Supported Devices and Features:

Firmware on the listed drives can be updated when attached to any of the following Storage Systems:         

  • HPE MSA 1040 SAN LFF Storage      
  • HPE MSA 1040 SAS LFF Storage
  • HPE MSA 2040 SAN LFF Storage    
  • HPE MSA 2040 SAS LFF Storage
  • HPE MSA 2042 SAN LFF Storage   
  • HPE MSA 2042 SAS LFF Storage   
  • HPE MSA 1050 SAN LFF Storage
  • HPE MSA 1050 SAS LFF Storage
  • HPE MSA 2050 SAN LFF Storage  
  • HPE MSA 2050 SAS LFF Storage
  • HPE MSA 2052 SAN LFF Storage  
  • HPE MSA 2052 SAS LFF Storage
  • HPE MSA 2040 LFF Disk Enclosure
  • HPE MSA 2050 LFF Disk Enclosure

Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issues were fixed in this firmware:

  • Fixed an internal drive reset due to unaligned write handling
  • Fixed an internal drive reset during power on sequence
  • Fixed issues where the drive became unresponsive during READ operations

Important

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

IMPORTANT: Ensure that no other user is performing administrative functions on the HPE MSA 1040/2040/1050/2050 Storage Array.

NOTE: Disk drive upgrades on the HPE MSA 1040/2040/1050/2050 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HPE Modular Storage Array Reference Guides. All firmware flash progress messages are logged to %systemdrive%\CPQSYSTEM\Log\MSA2000_IP.log and flash summary is logged to %systemdrive%\CPQSYSTEM\Log\cpqsetup.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HPE MSA 1040/2040/1050/2050 Storage Array.

IMPORTANT: HTTPS or Telnet service must be enabled on the arrays being updated and the corresponding connection must not be blocked by any firewall on the host system where the smart component is being executed. The Smart Component will manage the SFTP/FTP settings and PFU settings (enabled or disabled) in the arrays during flashing.

Revision History

Version:CD05 (2 Jul 2018)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issues were fixed in this firmware:

  • Fixed an internal drive reset due to unaligned write handling
  • Fixed an internal drive reset during power on sequence
  • Fixed issues where the drive became unresponsive during READ operations
Enhancements

The following enhancement was incorporated in this version:

  • Improved multiple sequential read performance

Version:C907 (13 Oct 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issues were fixed in this release of firmware:

  • Multiple self-initiated resets
  • Issue in 512 byte emulation mode which led to resource exhaustion
  • Sync issue when drive is in idle
Enhancements

Following enhancements were added to this version of firmware:

  • Improved performance in various workloads
  • Improved servo track settling and power calibration

Version:C7J0 (7 Oct 2015)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Following issues are fixed in this firmware:

  • Issues with Self-Initiated resets
  • Command timeouts
  • 0B/44/00 error
  • Errors found during WRITE

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.