Drivers & software

* RECOMMENDED * HP MSA 1040/2040 and P2000 G3 300GB, 450GB, 600GB and 900GB 6G SAS 10K rpm SFF Drive Models (EG0300FBVFL, EG0450FBVFM, EG0600FBVFP and EG0900FBVFQ) Hard Drive Firmware

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - SAS Storage Disk
Version: HPDE(2 Dec 2015)
Operating System(s): HP-UX 11.23
HP-UX 11.31 (IA)
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 10 (AMD64/EM64T)
SUSE Linux Enterprise Server 10 (x86)
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
VMware ESXi 5.0
VMware vSphere 5.1
VMware vSphere 5.5
VMware vSphere 6.0
Multi-part download
File name: HP_EG0300FBVFL_HPDE.fla (929 KB)
File name: HP_EG0450FBVFM_HPDE.fla (929 KB)
File name: HP_EG0600FBVFP_HPDE.fla (929 KB)
File name: HP_EG0900FBVFQ_HPDE.fla (929 KB)
The firmware available in this download is specifically packaged for flashing SFF hard drive models EG0300FBVFL(300G 6G SAS 10K), EG0450FBVFM(450G 6G SAS 10K), EG0600FBVFP(600G 6G SAS 10K) and EG0900FBVFQ(900G 6G SAS 10K) in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

Prerequisites:

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HP website and save the file to your local filesystem.

To ensure the integrity of your download, HPE recommends verifying your results with the following MD5 Checksum values:

85b2162a05347d071de9bb169915dbdf HP_EG0300FBVFL_HPDE.fla
77dc71b609ae2688923b9be744d27178 HP_EG0600FBVFP_HPDE.fla
82e097d7e4089fb8b03392ae8e1b1c79 HP_EG0900FBVFQ_HPDE.fla
0e04f043ac3351f88fe134cd81e42e54 HP_EG0450FBVFM_HPDE.fla

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Installation instructions using Storage Management Utility (SMU):

  1. Place the downloaded firmware file in a temporary directory.
  2. Stop I/O to vdisks before starting the firmware update.
  3. Login to the SMU. For SMU [v2] select Tools > Update Firmware and for SMU [v3] go to System > Actions > Update Firmware > Update Disk Drives. A table displays currently installed firmware versions.
  4. Select the drives to update. Click Browse and select the firmware file to install.
  5. Click Install Disk Firmware File or if using SMU [v3] click on OK button.
  6. Wait for progress messages to specify that the update is complete.
  7. In the SMU display, verify that the proper firmware version appears for each disk drive.

Installation instructions using FTP: 

Using the SMU, prepare to use FTP:

  • Determine the network-port IP addresses of the system controllers.
  • Verify that the system FTP service is enabled.
  • Verify that the user you will login, has permission to use the FTP interface and manage access rights.

Obtain address of the disks:

  • Obtain the address of each disk to be loaded in the form (for example, 0:1 and 1:9) and obtain the firmware revision of each of these disks.
  • Determine which disks need to be updated based on the revision.
  • Note: In SMU [v2], the disk addresses are displayed by clicking on each enclosure in the Configuration View, present in the left pane and then selecting the desired disk. The needed data is displayed in the fields labeled 'Enclosure ID', 'Slot' and 'Revision'. In SMU [v3], System->Front and put cursor on disk,Tool tip shows the location of the disk.
  • Note: In the CLI, enter 'show disks'. The required information is displayed in the columns labeled 'Location' and 'Revision'.

Instructions for updating disk firmware using FTP:

  1. Stop all I/O to vdisks before starting the firmware update.
  2. Place the downloaded firmware file in a temporary directory.
  3. Open a command prompt (Windows) or a terminal window (UNIX), and navigate to the directory containing the firmware file to load.
  4. Enter ftp <ip address>. (For example: ftp 10.1.0.9)
  5. Login via FTP with username and password having manage access rights
  6. To update a specific drive, Type put filename disk:enclosure-ID:slot-number where filename is the new firmware image to load.
  7. It typically takes several minutes for the firmware update progress messages to be displayed in this FTP interface during this time. WARNING! Do not power cycle or restart during the firmware update as this can result in loss of capabilities for this unit.
  8. Repeat steps 6-7 for each disk to update in each enclosure.
  9. Using SMU or CLI verify that the proper firmware version appears for each disk drive.

End User License Agreements:
HPE Software License Agreement v1


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HP website and save the file to your local filesystem.

Supported Devices and Features:

Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HP MSA 2040 SAN SFF Storage
  • HP MSA 2040 SAS SFF Storage
  • HP MSA 1040 SAN SFF Storage
  • HP MSA 1040 SAS SFF Storage
  • HP P2000 G3 10GbE iSCSI MSA Dual Controller SFF Array System
  • HP P2000 G3 iSCSI MSA Dual Controller SFF Array System
  • HP P2000 G3 SAS MSA Dual Controller SFF Array System
  • HP P2000 G3 MSA FC Dual Controller SFF Modular Smart Array System
  • HP P2000 G3 MSA FC/iSCSI Dual Combo Controller SFF Array

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issues are fixed in this firmware:

  • Fixed background seek algorithm to allow self-test to run in the background.
  • Fixed problem with SMART temp warning on a full cache hit read workload.
  • Enabled just in time seek (JIT) in low queue depth mixed sequential and random read workloads. JIT is a power saving feature. Seek acceleration is reduced, so the head arrives just in time for the target block. Customer will see reduced power draw in this workload.
  • Fixed rare servo bug. Change servo processor to reset pending request for external memory accesses. Servo processor reset did not stop a pending external memory access request and could cause an error for an external memory access timeout. Use system-level reset of servo processor block that covers the external memory access timeout instead of internal servo processor soft reset.

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HP website and save the file to your local filesystem.
Version:HPDE (2 Dec 2015)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issues are fixed in this firmware:

  • Fixed background seek algorithm to allow self-test to run in the background.
  • Fixed problem with SMART temp warning on a full cache hit read workload.
  • Enabled just in time seek (JIT) in low queue depth mixed sequential and random read workloads. JIT is a power saving feature. Seek acceleration is reduced, so the head arrives just in time for the target block. Customer will see reduced power draw in this workload.
  • Fixed rare servo bug. Change servo processor to reset pending request for external memory accesses. Servo processor reset did not stop a pending external memory access request and could cause an error for an external memory access timeout. Use system-level reset of servo processor block that covers the external memory access timeout instead of internal servo processor soft reset.

Version:HPDC (4 Nov 2014)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Following issue is fixed in this version:

  • This firmware release corrects a possible (E200 controller) drive discovery issue, due to the drive and controller timing not sequencing together.

Version:HPD9 (22 Jan 2014)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


  • Fix for code load can not change ‘D_Sense’ bit in mode page.
  • Fix bug by which Hard Errors were mistakenly converted to Soft Errors during Channel Averaging ERP steps.
  • Fix problem where SMART motor start, head load, spin-up time, and spin-up retry counts were not being checked on every spin-up attempt. They were only being checked on the first spin-up after a power cycle, but not on the subsequent motor stop/starts.
  • Fix for a command timeout when dual-port sequential commands are active and one link breaks.

 


Version:HPD8 (21 Aug 2013)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


  • This microcode corrects a potential command timeout issue, that could result from a possible rare occurrence of a servo stall condition.

Type: Firmware - SAS Storage Disk
Version: HPDE(2 Dec 2015)
Operating System(s):
HP-UX 11.23
HP-UX 11.31 (IA)
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 10 (AMD64/EM64T)
SUSE Linux Enterprise Server 10 (x86)
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
VMware ESXi 5.0
VMware vSphere 5.1
VMware vSphere 5.5
VMware vSphere 6.0

Description

The firmware available in this download is specifically packaged for flashing SFF hard drive models EG0300FBVFL(300G 6G SAS 10K), EG0450FBVFM(450G 6G SAS 10K), EG0600FBVFP(600G 6G SAS 10K) and EG0900FBVFQ(900G 6G SAS 10K) in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

Installation Instructions

Prerequisites:

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HP website and save the file to your local filesystem.

To ensure the integrity of your download, HPE recommends verifying your results with the following MD5 Checksum values:

85b2162a05347d071de9bb169915dbdf HP_EG0300FBVFL_HPDE.fla
77dc71b609ae2688923b9be744d27178 HP_EG0600FBVFP_HPDE.fla
82e097d7e4089fb8b03392ae8e1b1c79 HP_EG0900FBVFQ_HPDE.fla
0e04f043ac3351f88fe134cd81e42e54 HP_EG0450FBVFM_HPDE.fla

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Installation instructions using Storage Management Utility (SMU):

  1. Place the downloaded firmware file in a temporary directory.
  2. Stop I/O to vdisks before starting the firmware update.
  3. Login to the SMU. For SMU [v2] select Tools > Update Firmware and for SMU [v3] go to System > Actions > Update Firmware > Update Disk Drives. A table displays currently installed firmware versions.
  4. Select the drives to update. Click Browse and select the firmware file to install.
  5. Click Install Disk Firmware File or if using SMU [v3] click on OK button.
  6. Wait for progress messages to specify that the update is complete.
  7. In the SMU display, verify that the proper firmware version appears for each disk drive.

Installation instructions using FTP: 

Using the SMU, prepare to use FTP:

  • Determine the network-port IP addresses of the system controllers.
  • Verify that the system FTP service is enabled.
  • Verify that the user you will login, has permission to use the FTP interface and manage access rights.

Obtain address of the disks:

  • Obtain the address of each disk to be loaded in the form (for example, 0:1 and 1:9) and obtain the firmware revision of each of these disks.
  • Determine which disks need to be updated based on the revision.
  • Note: In SMU [v2], the disk addresses are displayed by clicking on each enclosure in the Configuration View, present in the left pane and then selecting the desired disk. The needed data is displayed in the fields labeled 'Enclosure ID', 'Slot' and 'Revision'. In SMU [v3], System->Front and put cursor on disk,Tool tip shows the location of the disk.
  • Note: In the CLI, enter 'show disks'. The required information is displayed in the columns labeled 'Location' and 'Revision'.

Instructions for updating disk firmware using FTP:

  1. Stop all I/O to vdisks before starting the firmware update.
  2. Place the downloaded firmware file in a temporary directory.
  3. Open a command prompt (Windows) or a terminal window (UNIX), and navigate to the directory containing the firmware file to load.
  4. Enter ftp <ip address>. (For example: ftp 10.1.0.9)
  5. Login via FTP with username and password having manage access rights
  6. To update a specific drive, Type put filename disk:enclosure-ID:slot-number where filename is the new firmware image to load.
  7. It typically takes several minutes for the firmware update progress messages to be displayed in this FTP interface during this time. WARNING! Do not power cycle or restart during the firmware update as this can result in loss of capabilities for this unit.
  8. Repeat steps 6-7 for each disk to update in each enclosure.
  9. Using SMU or CLI verify that the proper firmware version appears for each disk drive.

Release Notes

End User License Agreements:
HPE Software License Agreement v1


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HP website and save the file to your local filesystem.

Supported Devices and Features:

Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HP MSA 2040 SAN SFF Storage
  • HP MSA 2040 SAS SFF Storage
  • HP MSA 1040 SAN SFF Storage
  • HP MSA 1040 SAS SFF Storage
  • HP P2000 G3 10GbE iSCSI MSA Dual Controller SFF Array System
  • HP P2000 G3 iSCSI MSA Dual Controller SFF Array System
  • HP P2000 G3 SAS MSA Dual Controller SFF Array System
  • HP P2000 G3 MSA FC Dual Controller SFF Modular Smart Array System
  • HP P2000 G3 MSA FC/iSCSI Dual Combo Controller SFF Array

Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issues are fixed in this firmware:

  • Fixed background seek algorithm to allow self-test to run in the background.
  • Fixed problem with SMART temp warning on a full cache hit read workload.
  • Enabled just in time seek (JIT) in low queue depth mixed sequential and random read workloads. JIT is a power saving feature. Seek acceleration is reduced, so the head arrives just in time for the target block. Customer will see reduced power draw in this workload.
  • Fixed rare servo bug. Change servo processor to reset pending request for external memory accesses. Servo processor reset did not stop a pending external memory access request and could cause an error for an external memory access timeout. Use system-level reset of servo processor block that covers the external memory access timeout instead of internal servo processor soft reset.

Important

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Before upgrading firmware, ensure that the storage system configuration is stable and is not being reconfigured or changed in any way. If configuration changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that you have a full backup prior to the upgrade.

NOTE:

  • Drives of the same model in the storage system must have the same firmware revision.
  • To install this firmware, you must download the firmware package from the HP website and save the file to your local filesystem.

Revision History

Version:HPDE (2 Dec 2015)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following issues are fixed in this firmware:

  • Fixed background seek algorithm to allow self-test to run in the background.
  • Fixed problem with SMART temp warning on a full cache hit read workload.
  • Enabled just in time seek (JIT) in low queue depth mixed sequential and random read workloads. JIT is a power saving feature. Seek acceleration is reduced, so the head arrives just in time for the target block. Customer will see reduced power draw in this workload.
  • Fixed rare servo bug. Change servo processor to reset pending request for external memory accesses. Servo processor reset did not stop a pending external memory access request and could cause an error for an external memory access timeout. Use system-level reset of servo processor block that covers the external memory access timeout instead of internal servo processor soft reset.

Version:HPDC (4 Nov 2014)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Following issue is fixed in this version:

  • This firmware release corrects a possible (E200 controller) drive discovery issue, due to the drive and controller timing not sequencing together.

Version:HPD9 (22 Jan 2014)
Fixes

Upgrade Requirement:
Critical - HPE requires users update to this version immediately.


  • Fix for code load can not change ‘D_Sense’ bit in mode page.
  • Fix bug by which Hard Errors were mistakenly converted to Soft Errors during Channel Averaging ERP steps.
  • Fix problem where SMART motor start, head load, spin-up time, and spin-up retry counts were not being checked on every spin-up attempt. They were only being checked on the first spin-up after a power cycle, but not on the subsequent motor stop/starts.
  • Fix for a command timeout when dual-port sequential commands are active and one link breaks.

 


Version:HPD8 (21 Aug 2013)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


  • This microcode corrects a potential command timeout issue, that could result from a possible rare occurrence of a servo stall condition.