Printable version

Drivers & software

* RECOMMENDED * Firmware Flash Component for Linux - HP MSA 1040/2040 and P2000 G3 300GB, 450GB and 600GB 6G SAS 15K rpm LFF Drive Models ( ST3300657SS, ST3450857SS and ST3600057SS )

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - SAS Storage Disk
Version: 000B(2 Sep 2016)
Operating System(s): HP-UX 11.23
HP-UX 11.31 (IA)
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 Essentials
Microsoft Windows Server 2012 R2
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
VMware ESXi 5.0
VMware vSphere 5.1
VMware vSphere 5.5
VMware vSphere 6.0
File name: CP022190.scexe (7.1 MB)
This Linux Smart Component contains a firmware update for LFF hard drive models ST3300657SS (300GB 6G SAS 15K), ST3450857SS (450GB 6G SAS 15K) and ST3600057SS (600GB 6G SAS 15K) in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

Following enhancement was added to this version of firmware:

  •  Improvements to command processing which improve performance in certain workloads

Prerequisites:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040 and P2000 G3 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040 and P2000 G3 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

IMPORTANT: HTTPS/Telnet service must be enabled on the arrays being updated and the corresponding client interfaces enabled on the host system where the smart component is being executed. The Smart Component will manage the FTP enable / disable settings in array.


To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

201e0adb4892dca83e9eff194d5f3a7ae07d87b5f653b98833cb505442cde20d CP022190.scexe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

NOTE: When you  download this module from the HPE.com web site, you cannot double click on the link.  You will need to right click the link and select "save as" or similar option. This module is a SCEXE file.  It is a self extracting executable module. This module only operates from the Linux command line.

Installation instructions using Smart Component:

  1. Place the downloaded firmware package in a temporary directory.
  2. Open a Linux command console.
  3. From the directory containing the downloaded file, enable execute access to this module by entering chmod +x CPxxxxxx.scexe, where CPxxxxxx.scexe represents the downloaded file.
  4. Execute the Smart Component by entering a command similar to the following: ./CPxxxxxx.scexe --target <ip_address> --user <username> --passwd <password>
  5. Follow onscreen instructions.
  6. Wait for the installation to complete. Upon completion, a confirmation message is displayed.

NOTE:

  • In single-controller environments, stop all I/O to array before starting the firmware update.
  • Use the -e / --reflash or -f / --force option when flashing a device, even if it is up to date.
  • Use the -g / --downgrade option when downgrading.
  • For details on supported command options, see the online help by executing the command ./CPxxxxxx.scexe or ./CPxxxxxx.scexe -h / --help.
  • If the user name or password contains a special charecter, enclose the string in single quotes or enter a backslash (\) before the special charecter. For example, '!manage' or \!manage

End User License Agreements:
HPE Software License Agreement v1
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040 and P2000 G3 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040 and P2000 G3 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

IMPORTANT: HTTPS/Telnet service must be enabled on the arrays being updated and the corresponding client interfaces enabled on the host system where the smart component is being executed. The Smart Component will manage the FTP enable / disable settings in array.


Supported Devices and Features:

Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HPE MSA 2042 SAN LFF Storage   
  • HPE MSA 2042 SAS LFF Storage   
  • HPE MSA 2040 SAN LFF Storage    
  • HPE MSA 2040 SAS LFF Storage  
  • HPE MSA 1040 SAN LFF Storage      
  • HPE MSA 1040 SAS LFF Storage
  • HP P2000 G3 10GbE iSCSI MSA Dual Controller LFF Array System      
  • HP P2000 G3 iSCSI MSA Dual Controller LFF Array System      
  • HP P2000 G3 SAS MSA Dual Controller LFF Array System      
  • HP P2000 G3 MSA FC Dual Controller LFF Modular Smart Array System  
  • HP P2000 G3 MSA FC/iSCSI Dual Combo Controller LFF Array      
  • HP MSA 2040 LFF Disk Enclosure      
  • HP MSA2000 Dual I/O 3.5 inch 12 Drive Enclosure      
  • HP MSA2000 Single I/O 3.5 inch 12 Drive Enclosure      
  • HP P2000 Dual I/O LFF Drive Enclosure      
  • HP P2000 LFF Drive Enclosure I/O Module

 


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following fixes were added to this version of firmware:

  • Hard resets could hang the drive
  • Unexpected power loss/port loss
  • Various issues which would cause the LED to flash

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040 and P2000 G3 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040 and P2000 G3 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

IMPORTANT: HTTPS/Telnet service must be enabled on the arrays being updated and the corresponding client interfaces enabled on the host system where the smart component is being executed. The Smart Component will manage the FTP enable / disable settings in array.

Version:000B (2 Sep 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following fixes were added to this version of firmware:

  • Hard resets could hang the drive
  • Unexpected power loss/port loss
  • Various issues which would cause the LED to flash
Enhancements

Following enhancement was added to this version of firmware:

  •  Improvements to command processing which improve performance in certain workloads

Version:0008 (6 Sep 2011)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


This firmware update resolves the below issues:

  • During SAS 2.0 speed negotiations drive fails to see HARD RESET.
  • Drive does not acknowledge a hard reset and treats the reset as a link reset.
  • Hung Phy during disk reset test.
  • Seeks to the system cylinders dwell for a long time.
  • 04/8087/80 IOEDC error on write.

Version:0006 (14 Jul 2010)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Initial release with support for HP StorageWorks MSA2000 G2 and P2000 G3 MSA products


Type: Firmware - SAS Storage Disk
Version: 000B(2 Sep 2016)
Operating System(s):
HP-UX 11.23
HP-UX 11.31 (IA)
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 Essentials
Microsoft Windows Server 2012 R2
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
VMware ESXi 5.0
VMware vSphere 5.1
VMware vSphere 5.5
VMware vSphere 6.0

Description

This Linux Smart Component contains a firmware update for LFF hard drive models ST3300657SS (300GB 6G SAS 15K), ST3450857SS (450GB 6G SAS 15K) and ST3600057SS (600GB 6G SAS 15K) in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

Enhancements

Following enhancement was added to this version of firmware:

  •  Improvements to command processing which improve performance in certain workloads

Installation Instructions

Prerequisites:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040 and P2000 G3 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040 and P2000 G3 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

IMPORTANT: HTTPS/Telnet service must be enabled on the arrays being updated and the corresponding client interfaces enabled on the host system where the smart component is being executed. The Smart Component will manage the FTP enable / disable settings in array.


To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

201e0adb4892dca83e9eff194d5f3a7ae07d87b5f653b98833cb505442cde20d CP022190.scexe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

NOTE: When you  download this module from the HPE.com web site, you cannot double click on the link.  You will need to right click the link and select "save as" or similar option. This module is a SCEXE file.  It is a self extracting executable module. This module only operates from the Linux command line.

Installation instructions using Smart Component:

  1. Place the downloaded firmware package in a temporary directory.
  2. Open a Linux command console.
  3. From the directory containing the downloaded file, enable execute access to this module by entering chmod +x CPxxxxxx.scexe, where CPxxxxxx.scexe represents the downloaded file.
  4. Execute the Smart Component by entering a command similar to the following: ./CPxxxxxx.scexe --target <ip_address> --user <username> --passwd <password>
  5. Follow onscreen instructions.
  6. Wait for the installation to complete. Upon completion, a confirmation message is displayed.

NOTE:

  • In single-controller environments, stop all I/O to array before starting the firmware update.
  • Use the -e / --reflash or -f / --force option when flashing a device, even if it is up to date.
  • Use the -g / --downgrade option when downgrading.
  • For details on supported command options, see the online help by executing the command ./CPxxxxxx.scexe or ./CPxxxxxx.scexe -h / --help.
  • If the user name or password contains a special charecter, enclose the string in single quotes or enter a backslash (\) before the special charecter. For example, '!manage' or \!manage

Release Notes

End User License Agreements:
HPE Software License Agreement v1
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Important:

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040 and P2000 G3 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040 and P2000 G3 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

IMPORTANT: HTTPS/Telnet service must be enabled on the arrays being updated and the corresponding client interfaces enabled on the host system where the smart component is being executed. The Smart Component will manage the FTP enable / disable settings in array.


Supported Devices and Features:

Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HPE MSA 2042 SAN LFF Storage   
  • HPE MSA 2042 SAS LFF Storage   
  • HPE MSA 2040 SAN LFF Storage    
  • HPE MSA 2040 SAS LFF Storage  
  • HPE MSA 1040 SAN LFF Storage      
  • HPE MSA 1040 SAS LFF Storage
  • HP P2000 G3 10GbE iSCSI MSA Dual Controller LFF Array System      
  • HP P2000 G3 iSCSI MSA Dual Controller LFF Array System      
  • HP P2000 G3 SAS MSA Dual Controller LFF Array System      
  • HP P2000 G3 MSA FC Dual Controller LFF Modular Smart Array System  
  • HP P2000 G3 MSA FC/iSCSI Dual Combo Controller LFF Array      
  • HP MSA 2040 LFF Disk Enclosure      
  • HP MSA2000 Dual I/O 3.5 inch 12 Drive Enclosure      
  • HP MSA2000 Single I/O 3.5 inch 12 Drive Enclosure      
  • HP P2000 Dual I/O LFF Drive Enclosure      
  • HP P2000 LFF Drive Enclosure I/O Module

 


Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following fixes were added to this version of firmware:

  • Hard resets could hang the drive
  • Unexpected power loss/port loss
  • Various issues which would cause the LED to flash

Important

WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040 and P2000 G3 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040 and P2000 G3 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

IMPORTANT: HTTPS/Telnet service must be enabled on the arrays being updated and the corresponding client interfaces enabled on the host system where the smart component is being executed. The Smart Component will manage the FTP enable / disable settings in array.

Revision History

Version:000B (2 Sep 2016)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Following fixes were added to this version of firmware:

  • Hard resets could hang the drive
  • Unexpected power loss/port loss
  • Various issues which would cause the LED to flash
Enhancements

Following enhancement was added to this version of firmware:

  •  Improvements to command processing which improve performance in certain workloads

Version:0008 (6 Sep 2011)
Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


This firmware update resolves the below issues:

  • During SAS 2.0 speed negotiations drive fails to see HARD RESET.
  • Drive does not acknowledge a hard reset and treats the reset as a link reset.
  • Hung Phy during disk reset test.
  • Seeks to the system cylinders dwell for a long time.
  • 04/8087/80 IOEDC error on write.

Version:0006 (14 Jul 2010)
Enhancements

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.


Initial release with support for HP StorageWorks MSA2000 G2 and P2000 G3 MSA products


Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.