Printable version

Drivers & software

* RECOMMENDED * Firmware Flash Component for Linux - HP MSA 1040/2040 and P2000 G3 146GB, 300GB 6G SAS 15K rpm SFF Drive Models ( EH0146FBQDC and EH0300FBQDD )

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type: Firmware - SAS Storage Disk
Version: HPD5(7 Oct 2015)
Operating System(s): HP-UX 11.23
HP-UX 11.31 (IA)
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 10 (AMD64/EM64T)
SUSE Linux Enterprise Server 10 (x86)
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
VMware ESXi 5.0
VMware vSphere 5.1
VMware vSphere 5.5
VMware vSphere 6.0
File name: CP023367.scexe (6.5 MB)
This Linux Smart Component contains a firmware update for SFF hard drive models EH0146FBQDC (146GB 6G SAS 15K) and EH0300FBQDD (300GB 6G SAS 15K) in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

Prerequisites:

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040 and P2000 G3 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040 and P2000 G3 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040 and P2000 G3 Storage Arrays.


To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value:

95fda6bef7f3f816ce2413d4359678b2 CP023367.scexe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Installation instructions using Smart Component:

  1. Place the downloaded firmware package in a temporary directory.
  2. Open a Linux command console.
  3. From the directory containing the downloaded file, enable execute access to this module by entering chmod +x CPxxxxxx.scexe, where CPxxxxxx.scexe represents the downloaded file.
  4. Execute the Smart Component by entering a command similar to the following: ./CPxxxxxx.scexe --target <ip_address> --user <username> --passwd <password>
  5. Follow onscreen instructions.

NOTE:

  • Use the -e / --reflash or -f / --force option when flashing a device, even if it is up to date.
  • Use the -g / --downgrade option when downgrading.
  • For details on supported command options, see the online help by executing the command ./CPxxxxxx.scexe or ./CPxxxxxx.scexe -h / --help.
  • If the user name or password contains an exclamation mark (!), enclose the string in single quotes or enter a backslash (\) before the exclamation point. For example, '!manage' or \!manage

End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Important:

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040 and P2000 G3 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040 and P2000 G3 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040 and P2000 G3 Storage Arrays.


Supported Devices and Features:

Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HP MSA 2040 SAN SFF Storage
  • HP MSA 2040 SAS SFF Storage
  • HP MSA 1040 SAN SFF Storage
  • HP MSA 1040 SAS SFF Storage
  • HP P2000 G3 10GbE iSCSI MSA Dual Controller SFF Array System
  • HP P2000 G3 iSCSI MSA Dual Controller SFF Array System
  • HP P2000 G3 SAS MSA Dual Controller SFF Array System
  • HP P2000 G3 MSA FC Dual Controller SFF Modular Smart Array System
  • HP P2000 G3 MSA FC/iSCSI Dual Combo Controller SFF Array

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Following issue is fixed in this firmware:

  • HP ProLiant servers would power down due to a hard drive overtemp condition that was falsely reported.

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040 and P2000 G3 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040 and P2000 G3 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

Version:HPD5 (7 Oct 2015)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Following issue is fixed in this firmware:

  • HP ProLiant servers would power down due to a hard drive overtemp condition that was falsely reported.

Version:HPD3 (2 Dec 2013)
Fixes

Upgrade Requirement:
Critical - HP requires users update to this version immediately.


  • This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive.  The WRITE SAME command may be used during RAID ARRAY parity initialization

Type: Firmware - SAS Storage Disk
Version: HPD5(7 Oct 2015)
Operating System(s):
HP-UX 11.23
HP-UX 11.31 (IA)
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 10 (AMD64/EM64T)
SUSE Linux Enterprise Server 10 (x86)
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 12
VMware ESXi 5.0
VMware vSphere 5.1
VMware vSphere 5.5
VMware vSphere 6.0

Description

This Linux Smart Component contains a firmware update for SFF hard drive models EH0146FBQDC (146GB 6G SAS 15K) and EH0300FBQDD (300GB 6G SAS 15K) in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

Installation Instructions

Prerequisites:

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040 and P2000 G3 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040 and P2000 G3 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040 and P2000 G3 Storage Arrays.


To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value:

95fda6bef7f3f816ce2413d4359678b2 CP023367.scexe

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.


Installation:

Installation instructions using Smart Component:

  1. Place the downloaded firmware package in a temporary directory.
  2. Open a Linux command console.
  3. From the directory containing the downloaded file, enable execute access to this module by entering chmod +x CPxxxxxx.scexe, where CPxxxxxx.scexe represents the downloaded file.
  4. Execute the Smart Component by entering a command similar to the following: ./CPxxxxxx.scexe --target <ip_address> --user <username> --passwd <password>
  5. Follow onscreen instructions.

NOTE:

  • Use the -e / --reflash or -f / --force option when flashing a device, even if it is up to date.
  • Use the -g / --downgrade option when downgrading.
  • For details on supported command options, see the online help by executing the command ./CPxxxxxx.scexe or ./CPxxxxxx.scexe -h / --help.
  • If the user name or password contains an exclamation mark (!), enclose the string in single quotes or enter a backslash (\) before the exclamation point. For example, '!manage' or \!manage

Release Notes

End User License Agreements:
Hewlett-Packard End User License Agreement


Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Important:

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040 and P2000 G3 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040 and P2000 G3 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040 and P2000 G3 Storage Arrays.


Supported Devices and Features:

Firmware on the listed drives can be updated when attached to any of the following Storage Systems:

  • HP MSA 2040 SAN SFF Storage
  • HP MSA 2040 SAS SFF Storage
  • HP MSA 1040 SAN SFF Storage
  • HP MSA 1040 SAS SFF Storage
  • HP P2000 G3 10GbE iSCSI MSA Dual Controller SFF Array System
  • HP P2000 G3 iSCSI MSA Dual Controller SFF Array System
  • HP P2000 G3 SAS MSA Dual Controller SFF Array System
  • HP P2000 G3 MSA FC Dual Controller SFF Modular Smart Array System
  • HP P2000 G3 MSA FC/iSCSI Dual Combo Controller SFF Array

Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Following issue is fixed in this firmware:

  • HP ProLiant servers would power down due to a hard drive overtemp condition that was falsely reported.

Important

WARNING! Do not cycle power or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming.

CAUTION: Updating the firmware of disk drives in a virtual disk risks the loss of data and causes the drives to be temporarily inaccessible.

IMPORTANT: Ensure that no other user is performing administrative functions on the HP MSA 1040/2040 and P2000 G3 Storage Arrays.

NOTE: Disk drive upgrades on the HP MSA 1040/2040 and P2000 G3 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HP Modular Storage Array Reference Guides. All firmware flash progress messages are logged to /var/cpq/MSA2000_IP.log and flash summary is logged to /var/cpq/Component.log.

IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HP MSA 1040/2040 and P2000 G3 Storage Arrays.

Revision History

Version:HPD5 (7 Oct 2015)
Fixes

Upgrade Requirement:
Recommended - HP recommends users update to this version at their earliest convenience.


Following issue is fixed in this firmware:

  • HP ProLiant servers would power down due to a hard drive overtemp condition that was falsely reported.

Version:HPD3 (2 Dec 2013)
Fixes

Upgrade Requirement:
Critical - HP requires users update to this version immediately.


  • This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive.  The WRITE SAME command may be used during RAID ARRAY parity initialization

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.