* RECOMMENDED * HP P2000/MSA2000 146GB,300GB 10K SAS SFF Hard Drive (DG0146BARTP and DG0300BARTQ) Firmware.
By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note:
Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.
This package contains a firmware update for the hard drive models DG0146BARTP (each of 146GB 10K SAS) and DG0300BARTQ (each of 300GB 10K SAS) in P2000/MSA2000 configurations.
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
This firmware improves the hard drive servo control which reduces the number of positioning errors.
Prerequisites: WARNING! Do not cycle power or restart devices during a firmware update. If the update is
interrupted or there is a power failure, the module could become inoperative. If
this occurs, contact technical support. The module may need to be returned to
the factory for reprogramming.
CAUTION: Before upgrading firmware, ensure that the storage system configuration is
stable and is not being reconfigured or changed in any way. If configuration
changes are in progress, monitor them and wait until they are completed before
proceeding with the upgrade.
IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that
you have a full backup prior to the upgrade.
NOTE: Drives of the same model in the storage system must have the same firmware
revision.
NOTE: To install this firmware, you must download the firmware package from the HP
website and save the file to your local filesystem.
To ensure the integrity of your download, HP recommends verifying your results with
the following MD5 Checksum values:
b4866d3028bf63580136c7b831022756 |
HP_DG0146BARTP_HPD1.fla |
3ec7aa00e2f032059bf66f915dea3227 |
HP_DG0300BARTQ_HPD1.fla |
Installation: Installation instructions using Storage Management Utility (SMU)
- Place the downloaded firmware package in a temporary directory.
- Locate the firmware file in the extracted folder.
- Stop I/O to vdisks before starting the firmware update.
- Log
in to the SMU and, in the Configuration View panel, right-click the
system and select Tools > Update Firmware. A table displays
currently installed firmware versions.
- Select the drives to update.
- Click Browse and select the firmware file to install.
- Click Install Disk Firmware File. Wait for progress messages to specify that the update is complete.
- In the SMU display, verify that the proper firmware version appears for each module.
- If
the old firmware version is still displayed in the SMU, cycle power on
the enclosure. And then log in to the SMU to verify the firmware
version.
Installation instructions using FTP
-
Place the downloaded firmware package in a temporary
directory.
-
Locate the firmware file in the extracted folder.
-
Do
one of the following:
- To
update all drives of the type that the firmware applies to, proceed to the next
step.
- To
update specific drives, determine the enclosure number and slot number of the
drive.
-
Using the SMU, prepare to use FTP:
-
Determine the network-port IP addresses of the system
controllers.
-
Verify that the system FTP service is enabled.
-
Verify that the user you will log in as has permission to use
the FTP interface and has manage access rights.
-
Stop all I/O to vdisks before starting the firmware
update.
-
Open a command prompt (Windows) or a terminal window (UNIX),
and navigate to the directory containing the firmware file to load.
-
Enter ftp
<controller-network-address> . (For example: ftp 10.1.0.9 ) Log in as an FTP user. (P2000 environments: user = ftp password = !ftp ; MSA2000 environments: user = ftp password = flash ) To update a specific drive, enter: put <firmware-file>
disk:enclosure-ID>:slot-number flash .
-
If needed, repeat these steps to load the firmware on
additional drives.
-
Quit the FTP session.
-
In the SMU display, verify that the proper firmware version
appears for each module.
-
If
the old firmware version is still displayed in the SMU, cycle power on the
enclosure. And then log in to the SMU to verify the firmware version.
End User License Agreements: Hewlett-Packard End User License Agreement
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
Important:
CAUTION: Updating firmware on drives in a virtual disk causes the drives to be
temporarily inaccessible and increases the risk of data loss
IMPORTANT: Drive upgrades are an offline process. All host and array I/O must be stopped
prior to the upgrade.
Notes:
Deliverable Name: HP P2000/MSA2000 146GB,300GB 10K SAS SFF Hard Drive (DG0146BARTP and DG0300BARTQ) Firmware.
Release Version and/or Date: HPD1
Last Recommended or Critical Version: NA
Previous Version of Firmware: HPD0
Enhancements/New Features:
- This firmware improves the hard drive servo control which reduces the number of positioning errors.
Problems: None
Known Issues: None
Supported Devices and Features: Firmware on the listed drives can be updated when attached to any P2000 G3 MSA or MSA2000 G2 array controller enclosure.
CAUTION: Updating firmware on drives in a virtual disk causes the drives to be
temporarily inaccessible and increases the risk of data loss
IMPORTANT: Drive upgrades are an offline process. All host and array I/O must be stopped
prior to the upgrade.
Version:HPD1 (8 Jul 2011)
Enhancements
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
This firmware improves the hard drive servo control which reduces the number of positioning errors.
Type: |
Firmware - SAS Storage Disk |
Version: |
HPD1(8 Jul 2011) |
Operating System(s): |
HP-UX 11.23
|
HP-UX 11.31 (IA)
|
Microsoft Windows Server 2003
|
Microsoft Windows Server 2003 64-Bit Edition
|
Microsoft Windows Server 2003 for 64-bit Extended Systems
|
Microsoft Windows Server 2008 Itanium
|
Microsoft Windows Server 2008 R2
|
Microsoft Windows Server 2008 R2 for Itanium-Based Systems
|
Microsoft Windows Server 2008 W32
|
Microsoft Windows Server 2008 x64
|
Red Hat Enterprise Linux 4 (AMD64/EM64T)
|
Red Hat Enterprise Linux 4 (x86)
|
Red Hat Enterprise Linux 5 Server (x86)
|
Red Hat Enterprise Linux 5 Server (x86-64)
|
Solaris 10 for x86 Systems
|
SUSE Linux Enterprise Server 10 (AMD64/EM64T)
|
SUSE Linux Enterprise Server 10 (x86)
|
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
|
SUSE Linux Enterprise Server 11 (x86)
|
VMware ESX/ESXi 4.0
|
VMware ESX/ESXi Server 3.5
|
|
Description
This package contains a firmware update for the hard drive models DG0146BARTP (each of 146GB 10K SAS) and DG0300BARTQ (each of 300GB 10K SAS) in P2000/MSA2000 configurations.
Enhancements
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
This firmware improves the hard drive servo control which reduces the number of positioning errors.
Installation Instructions
Prerequisites: WARNING! Do not cycle power or restart devices during a firmware update. If the update is
interrupted or there is a power failure, the module could become inoperative. If
this occurs, contact technical support. The module may need to be returned to
the factory for reprogramming.
CAUTION: Before upgrading firmware, ensure that the storage system configuration is
stable and is not being reconfigured or changed in any way. If configuration
changes are in progress, monitor them and wait until they are completed before
proceeding with the upgrade.
IMPORTANT: As with any firmware upgrade, it is a recommended best practice to ensure that
you have a full backup prior to the upgrade.
NOTE: Drives of the same model in the storage system must have the same firmware
revision.
NOTE: To install this firmware, you must download the firmware package from the HP
website and save the file to your local filesystem.
To ensure the integrity of your download, HP recommends verifying your results with
the following MD5 Checksum values:
b4866d3028bf63580136c7b831022756 |
HP_DG0146BARTP_HPD1.fla |
3ec7aa00e2f032059bf66f915dea3227 |
HP_DG0300BARTQ_HPD1.fla |
Installation: Installation instructions using Storage Management Utility (SMU)
- Place the downloaded firmware package in a temporary directory.
- Locate the firmware file in the extracted folder.
- Stop I/O to vdisks before starting the firmware update.
- Log
in to the SMU and, in the Configuration View panel, right-click the
system and select Tools > Update Firmware. A table displays
currently installed firmware versions.
- Select the drives to update.
- Click Browse and select the firmware file to install.
- Click Install Disk Firmware File. Wait for progress messages to specify that the update is complete.
- In the SMU display, verify that the proper firmware version appears for each module.
- If
the old firmware version is still displayed in the SMU, cycle power on
the enclosure. And then log in to the SMU to verify the firmware
version.
Installation instructions using FTP
-
Place the downloaded firmware package in a temporary
directory.
-
Locate the firmware file in the extracted folder.
-
Do
one of the following:
- To
update all drives of the type that the firmware applies to, proceed to the next
step.
- To
update specific drives, determine the enclosure number and slot number of the
drive.
-
Using the SMU, prepare to use FTP:
-
Determine the network-port IP addresses of the system
controllers.
-
Verify that the system FTP service is enabled.
-
Verify that the user you will log in as has permission to use
the FTP interface and has manage access rights.
-
Stop all I/O to vdisks before starting the firmware
update.
-
Open a command prompt (Windows) or a terminal window (UNIX),
and navigate to the directory containing the firmware file to load.
-
Enter ftp
<controller-network-address> . (For example: ftp 10.1.0.9 ) Log in as an FTP user. (P2000 environments: user = ftp password = !ftp ; MSA2000 environments: user = ftp password = flash ) To update a specific drive, enter: put <firmware-file>
disk:enclosure-ID>:slot-number flash .
-
If needed, repeat these steps to load the firmware on
additional drives.
-
Quit the FTP session.
-
In the SMU display, verify that the proper firmware version
appears for each module.
-
If
the old firmware version is still displayed in the SMU, cycle power on the
enclosure. And then log in to the SMU to verify the firmware version.
Release Notes
End User License Agreements: Hewlett-Packard End User License Agreement
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
Important:
CAUTION: Updating firmware on drives in a virtual disk causes the drives to be
temporarily inaccessible and increases the risk of data loss
IMPORTANT: Drive upgrades are an offline process. All host and array I/O must be stopped
prior to the upgrade.
Notes:
Deliverable Name: HP P2000/MSA2000 146GB,300GB 10K SAS SFF Hard Drive (DG0146BARTP and DG0300BARTQ) Firmware.
Release Version and/or Date: HPD1
Last Recommended or Critical Version: NA
Previous Version of Firmware: HPD0
Enhancements/New Features:
- This firmware improves the hard drive servo control which reduces the number of positioning errors.
Problems: None
Known Issues: None
Supported Devices and Features: Firmware on the listed drives can be updated when attached to any P2000 G3 MSA or MSA2000 G2 array controller enclosure.
Important
CAUTION: Updating firmware on drives in a virtual disk causes the drives to be
temporarily inaccessible and increases the risk of data loss
IMPORTANT: Drive upgrades are an offline process. All host and array I/O must be stopped
prior to the upgrade.
Revision History
Version:HPD1 (8 Jul 2011)
Enhancements
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
This firmware improves the hard drive servo control which reduces the number of positioning errors.
|
|