The following tables provide information on the switch (management and data) specifications that have been validated as part of a blueprint, reason to consider them, and customization options.
Management switch
HPE FlexFabrix 5900
|
Validated Configuration
|
HPE FlexFabric 5900AF 48G 4XG 2QSFP+ Switch
|
Blueprint Design Consideration
|
1*switch for management traffic
Cut-through with ultra-low-latency and wired speed
Non-blocking uplink bandwidth to customer network (10G and 40G supported)
|
Customization Option
|
1*switch for management traffic:
1G mgmt. port for switch OOBM connectivity
nx1G ports for OOBM access to server ILO and switch mgmt. port.
4x10G/2x40G uplink ports to customer network
|
Data switch
HPE FlexFabrix 5950
|
Validated Configuration
|
HPE FlexFabric 5950 32QSFP28 Switch
|
Blueprint Design Consideration
|
Cut-through with ultra-low latency and wire speed
VXLAN L2 and L3 VTEP,OVSDB support for virtualized environments
High-density 100GbE/40GbE/25GbE/10GbE spine/ToR connectivity
|
Customization Option
|
Supports 10G and 25G for Control, Storage and VNF traffic
3x100G for Switch High Availability for Comware and 2x100G for Cumulus IRF in Comware
Maximum 9 device can be a part of single IRF domain for 5950
|
HPE SN2100M
|
Validated Configuration
|
HPE SN2100M 100GbE 16QSFP28 ONIE Power to Connector Airflow Half Width Switch
|
Blueprint Design Consideration
|
Wire speed L2 and L3 forwarding
Low cut-through latency of 300ns port to port
VXLAN Hardware VTEP – L2 GW
ONIE supported
|
Customization Option
|
Supports 10G and 25G for Control, Storage and VNF traffic
For High Availability 2x100G ports for Cumulus CLAG in Cumulus
Maximum 2 device can be part of CLAG for SN2100.
|