Symptom Cumulus version is incorrect
Action-
Re-install both the data switches with intended cumulus operating system. For more information, see
Installing Cumulus Linux NOS and license on ONIE switches.
-
Re-run the switch automation. For more information, see
Deploying switch configuration.
-
If autodeploy is used for installation, run the
nps autodeploy
command again.
-
If manual procedure is used for installation, install operating system through image service using the following:
- Delete the image service pod using the following command:
nps baremetal -a delete -nos <nos_type>
Where,
nos
is the Network Operating System and supported
<nos_type>
is
cumulus
.
- Bring up image-service pod using the following command:
nps baremetal -a install -nos <nos_type> -l debug -os_type rhel -iso_path <iso_filepath_with_filename> -pxe_vlanid <PXE_vlan_id>
Where,
iso_filepath_with_filename
is the RHEL ISO filename with full path
PXE_vlan_id
is the OCP/PXE VLAN ID.
nos
is Network Operating System and the supported
<nos_type>
is
cumulus
.
NOTE: For any installation issue, check the log file
/var/nps/logs/<topology_name>/baremetal_install.log
and take necessary actions.
- After the image-service-0 pod is up and running, start one time pxeboot for the failed servers using following command:
nps baremetal -a temp-pxeboot -sl <iLO IP1, iLO IP2> -l debug
Wait for some time for the OS to get installed.
- Verify the baremetal installation status again using the command:
nps show --service baremetal