NIC based settings for hardware profiles

Specific NIC based settings based on role of the server

Table 23: NIC based settings for master profile
NIC based setting Value Description
EmbNicEnable Disabled Embedded 1G NIC is disabled.
FlexLom1Enable Auto FLR NIC is enabled.
FlexLOM 1:Port 1 NetworkBoot First port of FLR NIC is enabled for networkboot.
FlexLOM 1:Port 2 Disabled Second port of FLR NIC is disabled for networkboot.
boot_order
"HD.EmbRAID.1.*",
"NIC.FlexLOM.1.1.IPv4"
Logical drive is set as first device and PXE IPv4 of first port in FLR NIC is set as second device in the server boot order.
Table 24: NIC based settings for worker profile
NIC based setting Value Description
EmbNicEnable Disabled Embedded 1G NIC is disabled.
FlexLom1Enable Auto FLR NIC is enabled.
PciSlot1Enable Auto NIC in PCIe Slot 1 is enabled.
PciSlot3Enable Auto NIC in PCIe Slot 3 is enabled.
FlexLOM 1:Port 1 NetworkBoot First port of FLR NIC is enabled for networkboot.
FlexLOM 1:Port 2 Disabled Second port of FLR NIC is disabled for networkboot.
Slot 1:Port 1 Disabled First port of PCIe Slot 1 is disabled for networkboot.
Slot 1:Port 2 Disabled Second port of PCIe Slot 1 is disabled for networkboot.
Slot 3:Port 1 Disabled First port of PCIe Slot 3 is disabled for networkboot.
Slot 3:Port 2 Disabled Second port of PCIe Slot 3 is disabled for networkboot.
boot_order
"HD.EmbRAID.1.*",
"NIC.FlexLOM.1.1.IPv4"
Logical drive is set as a first device and PXE IPv4 of first port in FLR NIC is set as a second device in the server boot order.
Table 25: NIC based settings for AMD master profile
NIC based setting Value Description
PciSlot10Enable Auto OCP NIC is enabled. PCIe slot 10 is allocated for OCP NIC.
Slot 10:Port 1 NetworkBoot First port of OCP NIC is enabled for networkboot.
Slot 10:Port 2 Disabled Second port of OCP NIC is disabled for networkboot.
boot_order
"HD.Slot.12.*",
"OCP.Slot.10.1.IPv4"
Logical drive is set as a first device and PXE IPv4 of first port in OCP NIC is set as a second device in the server boot order.
Table 26: NIC based settings for AMD worker profile
NIC based setting Value Description
PciSlot10Enable Auto OCP NIC is enabled. PCIe slot 10 is allocated for OCP NIC.
PciSlot1Enable Auto NIC in PCIe Slot 1 is enabled.
PciSlot3Enable Auto NIC in PCIe Slot 3 is enabled.
Slot 10:Port 1 NetworkBoot First port of OCP NIC is enabled for networkboot.
Slot 10:Port 2 Disabled Second port of OCP NIC is disabled for networkboot.
Slot 1:Port 1 Disabled First port of PCIe Slot 1 is disabled for networkboot.
Slot 1:Port 2 Disabled Second port of PCIe Slot 1 is disabled for networkboot.
Slot 3:Port 1 Disabled First port of PCIe Slot 3 is disabled for networkboot.
Slot 3:Port 2 Disabled Second port of PCIe Slot 3 is disabled for networkboot.
boot_order
"HD.Slot.12.*",
"OCP.Slot.10.1.IPv4"
Logical drive is set as first device and PXE IPv4 of first port in OCP NIC is set as second device in the server boot order.
NOTE: These parameters are used for RHCOS installation.
BIOS settings Value Description
PostDiscoveryMode ForceFullDiscovery

After the creation of a logical drive, the system must perform a full connect (discover), instead of performing selective connect. The logical drive name is not displayed in the Server Boot Order in iLO. Set the UEFI POST Discovery Mode to ForceFullDiscovery in the BIOS configuration to display the logical drive name.

This is applicable to RHCOS bootstrap/master/worker nodes.

PostDiscoveryMode Auto

After setting the Server Boot Order, the UEFI POST Discovery Mode is reset to Auto.