display fcs ie
Use display fcs ie to display IE information.
Syntax
display fcs ie [ vsan vsan-id [ nwwn wwn ] ] [ verbose ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this command displays the IE information in all VSANs. On an FCF-NPV switch, this command displays the IE information in only VSANs operating in FCF mode.
nwwn wwn: Specifies a node by its WWN in the format of xx:xx:xx:xx:xx:xx:xx:xx (hexadecimal). If you do not specify a node, this command displays the IE information for all nodes.
verbose: Displays detailed IE information. If you do not specify this keyword, the command displays brief IE information.
Examples
# Display the IE information in all VSANs.
<Sysname> display fcs ie IE List for VSAN 1: IE WWN Domain ID Mgmt addr list Logical name 10:00:00:11:22:00:01:01 0x01 snmp://192.168.6.100 Sysname snmp://192.168.0.100 10:00:00:11:22:00:01:02 0x02 snmp://192.168.6.101 Sysname Total 2 IEs in Fabric. IE List for VSAN 2: IE WWN Domain ID Mgmt addr list Logical name 10:00:00:11:22:00:01:01 0x01 snmp://192.168.6.100 Sysname Total 1 IEs in Fabric.
# Display the IE information in VSAN 1.
<Sysname> display fcs ie vsan 1 IE List for VSAN 1: IE WWN Domain ID Mgmt addr list Logical name 10:00:00:11:22:00:01:01 0x01 snmp://192.168.6.100 Sysname snmp://192.168.0.100 10:00:00:11:22:00:01:02 0x02 snmp://192.168.6.101 Sysname Total 2 IEs in Fabric.
# Display the brief IE information for the node with WWN 10:00:00:11:22:00:01:01 in VSAN 1.
<Sysname> display fcs ie vsan 1 nwwn 10:00:00:11:22:00:01:01 IE WWN Domain ID Mgmt addr list Logical name 10:00:00:11:22:00:01:01 0x01 snmp://192.168.6.100 Sysname snmp://192.168.0.100
# Display the detailed IE information for the node with WWN 10:00:00:11:22:00:01:01 in VSAN 1.
<Sysname> display fcs ie vsan 1 nwwn 10:00:00:11:22:00:01:01 verbose IE Attributes: IE WWN : 10:00:00:11:22:00:01:01 IE type : Switch Domain ID : 0x01 Fabric name : 10:00:00:11:22:00:01:01 Logical name : Sysname Management address list: snmp://192.168.6.100 snmp://192.168.0.100 Information list : Vendor name : abc, Inc. Model name/number: DS-A8263-M5 Release code : 1.3(2a)
# Display the detailed IE information in all VSANs.
<Sysname> display fcs ie verbose IE List for VSAN 1: IE Attributes: IE WWN : 10:00:00:11:22:00:01:01 IE type : Switch Domain ID : 0x01 Fabric name : 10:00:00:11:22:00:01:01 Logical name : Sysname Management address list: snmp://192.168.6.100 snmp://192.168.0.100 Information list : Vendor name : abc, Inc. Model name/number: DS-A8263-M5 Release code : 1.3(2a) Total 1 IEs in Fabric. IE List for VSAN 2: IE Attributes: IE WWN : 10:00:00:11:22:00:01:01 IE type : Switch Domain ID : 0x01 Fabric name : 10:00:00:11:22:00:01:01 Logical name : Sysname Management address list: snmp://192.168.6.100 snmp://192.168.0.100 Information list : Vendor name : abc, Inc. Model name/number: DS-A8263-M5 Release code : 1.3(2a) Total 1 IEs in Fabric.
Table 54: Command output
Field | Description |
---|---|
IE type | The IE type can only be Switch. Unknown is displayed for all other types. |
Fabric name | Name of the fabric where the IE resides. Unknown indicates that the fabric name is not obtained from the IE. |
Logical name | Device name of the IE. Unknown indicates that the device name is not obtained from the IE. |
Mgmt addr list Management address list |
|
Information list | Includes vendor name, model name/number, and release code. Unknown indicates that the information list is not obtained from the IE. |
Related commands
fcs discovery start