Configuring a remote CCC connection

To configure a remote CCC connection, perform the following configurations on the PE and P devices:

Follow these guidelines when you configure a remote CCC connection:

To configure a remote CCC connection:

Step

Command

Remarks

1. Enter system view.

system-view

N/A

2. Enter cross-connect group view.

xconnect-group group-name

N/A

3. Enter cross-connect view.

connection connection-name

N/A

4. Create a remote CCC connection.

ccc in-label in-label-value out-label out-label-value { nexthop nexthop | out-interface interface-type interface-number } [ pw-class class-name ]

By default, no remote CCC connection is created.

Use the out-interface keyword to specify the outgoing interface only on a point-to-point link. On other types of interfaces such as Layer 3 Ethernet interface, VLAN interface, and Layer 3 aggregate interface, you must use the nexthop keyword to specify the IP address of the next hop.