Configuring a cross-connect
Step | Command | Remarks |
---|---|---|
1. Enter system view. | system-view | N/A |
2. Create a cross-connect group and enter cross-connect group view. | xconnect-group group-name | By default, no cross-connect group is created. |
3. (Optional.) Configure a description for the cross-connect group. | description text | By default, no description is configured for the cross-connect group. |
4. (Optional.) Enable the cross-connect group. | undo shutdown | By default, the cross-connect group is enabled. |
5. Create a cross-connect and enter cross-connect view. | connection connection-name | By default, no cross-connect is created. |
6. Configure an MTU for the PW. | mtu mtu | The default MTU is 1500 bytes. The two PEs on an LDP PW must have the same MTU configured for the PW. Otherwise, the PW cannot go up. |