PBB frame format
Figure 73 shows the format of a PBB frame.
Figure 73: PBB frame format
Table 18 describes key fields in the frame.
Table 18: PBB frame fields
Field | Full name | Description |
---|---|---|
B-DA | Backbone destination MAC address | Destination B-MAC, outer destination MAC address in a PBB frame. It is the MAC address of the BEB at the destination end of the PBBN tunnel. The combination of B-DA and B-SA is B-MAC. |
B-SA | Backbone source MAC address | Source B-MAC, outer source MAC address in a PBB frame. It is the MAC address of the BEB at the source end of the PBBN tunnel. The combination of B-DA and B-SA is B-MAC. |
B-Tag | Backbone VLAN tag | B-VLAN tag, outer VLAN tag in a PBB frame. It indicates the VLAN information and priority information of the frame within the PBBN. The TPID in a B-Tag is 0x8100. |
I-Tag | Backbone service instance tag | Service identifier of a PBB frame. The I-Tag contains the following fields:
|
S-Tag | Service provider VLAN tag | Outer VLAN tag of the frame in the PBN, which indicates the VLAN and priority information of the frame within the PBN. |
C-Tag | Customer VLAN tag | Inner VLAN tag of the frame in the PBN, which indicates the VLAN and priority information of the frame within the customer network. |
For more information about TPID, see "Configuring VLANs."