oam global errored-frame-seconds window
Use oam global errored-frame-seconds window to set the global errored frame seconds event detection window.
Use undo oam global errored-frame-seconds window to restore the default.
Syntax
oam global errored-frame-seconds window window-value
undo oam global errored-frame-seconds window
Default
The global errored frame seconds event detection window is 60000 milliseconds.
Views
System view
Predefined user roles
network-admin
Parameters
window-value: Specifies the errored frame seconds event detection window in the range of 100 to 9000 and in steps of 10 (in 100 milliseconds).
Usage guidelines
The value of the errored frame seconds event triggering threshold cannot be greater than the value of the errored frame seconds event detection window (in seconds). Otherwise, errored frame seconds events cannot be generated.
The configuration in system view takes effect on all ports, but has a lower precedence than the configuration in port view.
Examples
# Set the errored frame seconds event detection window to 10000 milliseconds.
<Sysname> system-view [Sysname] oam global errored-frame-seconds window 100
Related commands
display oam configuration
display oam link-event
oam errored-frame-seconds period
oam global errored-frame-seconds threshold