oam errored-frame window

Use oam errored-frame window to set the errored frame event detection window.

Use undo oam errored-frame window to restore the default.

Syntax

oam errored-frame window window-value

undo oam errored-frame window

Default

The port uses the global setting.

Views

Layer 2 Ethernet port view, Layer 3 Ethernet port view

Predefined user roles

network-admin

Parameters

window-value: Specifies the errored frame event detection window in the range of 10 to 600 and in steps of 10 (in 100 milliseconds).

Usage guidelines

The configuration in port view takes effect on the specified port. For a port, the configuration in port view takes precedence.

Examples

# Set the errored frame event detection window on Ten-GigabitEthernet 1/0/1 to 2000 milliseconds.

<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] oam errored-frame window 20

Related commands