Configuring the temperature alarm thresholds

The device monitors its temperature through temperature sensors, based on the following thresholds:

When the temperature drops below the low-temperature threshold or reaches the high-temperature warning threshold, the device performs the following tasks:

When the temperature reaches the high-temperature alarming threshold, the device performs the following tasks:

To configure the temperature alarm thresholds:

Step

Command

Remarks

1. Enter system view.

system-view

N/A

2. Configure the temperature alarm thresholds.

temperature-limit slot slot-number hotspot sensor-number lowlimit warninglimit [ alarmlimit ]

To view the default settings, use the undo temperature-limit command to restore the defaults and then execute the display environment command.

The high-temperature alarming threshold must be higher than the high-temperature warning threshold. The high-temperature warning threshold must be higher than the low-temperature threshold.