Configuring parity error alarm for entries on forwarding chips
The device detects parity errors in entries on forwarding chips. The parity error alarm feature enables the device to perform the following operations:
Collects statistics for parity errors at an interval, and issues an alarm if the number of the errors exceeds the alarm threshold.
Generates logs for the detected parity errors.
To configure parity error alarm for entries on forwarding chips:
Step | Command | Remarks |
---|---|---|
1. Enter system view. | system-view | N/A |
2. Set the parity error statistics interval for entries on forwarding chips. | parity-error monitor period value | By default, the parity error statistics interval is 60 seconds. |
3. Set the parity error alarm threshold for entries on forwarding chips. | parity-error monitor threshold value | By default, the parity error alarm threshold is 5000. |
4. Enable parity error logging for entries on forwarding chips. | parity-error monitor log enable | By default, parity error logging is disabled for entries on forwarding chips. |