Configuring parity error alarm for entries on forwarding chips

The device detects parity errors in entries on forwarding chips. The parity error alarm feature enables the device to perform the following operations:

To configure parity error alarm for entries on forwarding chips:

Step

Command

Remarks

1. Enter system view.

system-view

N/A

2. Set the parity error statistics interval for entries on forwarding chips.

parity-error monitor period value

By default, the parity error statistics interval is 60 seconds.

3. Set the parity error alarm threshold for entries on forwarding chips.

parity-error monitor threshold value

By default, the parity error alarm threshold is 5000.

4. Enable parity error logging for entries on forwarding chips.

parity-error monitor log enable

By default, parity error logging is disabled for entries on forwarding chips.