Configuration guidelines
Follow these guidelines when you configure ARP filtering:
You can configure a maximum of eight permitted entries on an interface.
Do not configure both the arp filter source and arp filter binding commands on an interface.
If ARP filtering works with ARP attack detection, MFF, and ARP snooping, ARP filtering applies first.