Fixed power supply failure

The HPE 5130 24G 4SFP+ EI, HPE 5130 24G 2SFP+ 2XGT EI, and HPE 5130 24G 4SFP+ EI BR switches use fixed power supplies and support only AC power input.

The HPE 5130 24G PoE+ 4SFP+ (370W) EI, HPE 5130 48G 4SFP+ EI, HPE 5130 24G PoE+ 4SFP+ (370W) EI BR, HPE 5130 48G PoE+ 4SFP+ (370W) EI BR, HPE 5130 48G 2SFP+ 2XGT EI, HPE 5130 24G PoE+ 2SFP+ 2XGT (370W) EI, HPE 5130 48G PoE+ 2SFP+ 2XGT (370W) EI, and HPE 5130 48G PoE+ 4SFP+ (370W) EI switches use fixed power supplies and support AC power input, RPS power input, and concurrent AC and RPS DC inputs. For these switch models, the "Power x failed" message is displayed as long as only one power supply is operating because the switch cannot identify whether the other power supply is not connected or has failed. In this case, see this section to determine the power supply state.

To identify a fixed power supply failure, examine the system status LED and the RPS status LED of the switch.

Table 8: Fixed power supply LED description

LED

Mark

Status

Description

System status LED

SYS

Off

The switch is powered off.

RPS status LED

RPS

Steady green

The AC input is normal, and the RPS is in position or working normally.

Steady yellow

RPS power input is normal, but AC input has failed or AC input is not connected.

Off

No RPS is connected.