cfd cc interval
Syntax
cfd cc interval interval-value service-instance instance-id
undo cfd cc interval service-instance instance-id
View
System view
Default level
2: System level
Parameters
interval interval-value: Specifies the value of the interval field in CCM messages, which ranges from 4 to 7.
service-instance instance-id: Specifies the service instance ID, ranging from 1 to 32767.
Description
Use cfd cc interval to set the value of the interval field in the CCM messages.
Use undo cfd cc interval to restore default.
By default, the value of this field is 4 for all CCMs sent.
The relationship between the interval field value in the CCM messages, the interval for sending CCM messages, and the timeout time of the remote MEP is shown in Table 7.
Table 7: Relationship of interval field value, interval for sending CCMs, and timeout time of remote MEP
Interval field value | Interval for sending CCMs | Timeout time of remote MEP |
---|---|---|
4 | 1 second | 3.5 seconds |
5 | 10 seconds | 35 seconds |
6 | 60 seconds | 210 seconds |
7 | 600 seconds | 2100 seconds |
Related commands: cfd cc enable.
Examples
# Set the value of the interval field in CCMs sent by MEPs in service instance 2 to 7.
<Sysname> system-view [Sysname] cfd cc interval 7 service-instance 2