Associating an ERPS ring member port with a track entry
Restrictions and guidelines
Before you associate a port with a track entry, make sure the port has joined an ERPS instance.
Procedure
Enter system view.
system-view
Enter Layer 2 Ethernet interface view or Layer 2 aggregate interface view.
interface interface-type interface-number
Associate an ERPS ring member port with a track entry.
port erps ring ring-id instance instance-id track track-entry-index
By default, an ERPS ring member port is not associated with any track entries.