Configuring EAIS

Restrictions and guidelines

Follow these guidelines when you configure EAIS on a MEP:

Procedure

  1. Enter system view.

    system-view

  2. Enable port status-AIS collaboration.

    cfd ais-track link-status global

    By default, port status-AIS collaboration is disabled.

  3. Enter Layer 2 Ethernet interface view or Layer 2 aggregate interface view.

    interface interface-type interface-number

  4. Configure the EAIS frame transmission level.

    cfd ais-track link-status level level-value

    By default, the EAIS frame transmission level is not configured.

  5. Configure the EAIS frame transmission interval.

    cfd ais-track link-status period period-value

    By default, the EAIS frame transmission interval is not configured.

  6. Specify the VLANs where the EAIS frames can be transmitted.

    cfd ais-track link-status vlan vlan-list

    By default, the EAIS frames can only be transmitted within the default VLAN of the port.

    The EAIS frames are transmitted within the intersection of the VLANs specified with this command and the existing VLANs on the device.