timers

Use timers to configure RIPng timers.

Use undo timers to restore the default.

Syntax

timers { garbage-collect garbage-collect-value | suppress suppress-value | timeout timeout-value | update update-value } *

undo timers { garbage-collect | suppress | timeout | update } *

Default

The garbage-collect timer is 120 seconds, the suppress timer is 120 seconds, the timeout timer is 180 seconds, and the update timer is 30 seconds.

Views

RIPng view

Predefines user roles

network-admin

mdc-admin

Parameters

garbage-collect-value: Sets the garbage-collect timer in the range of 1 to 86400 seconds.

suppress-value: Sets the suppress timer in the range of 0 to 86400 seconds.

timeout-value: Sets the timeout timer in the range of 1 to 86400 seconds.

update-value: Sets the update timer in the range of 1 to 86400 seconds.

Usage guidelines

RIPng has the following timers:

As a best practice, do not change the default values of these timers.

The timer lengths must be kept consistent on all routers in the network.

Examples

# Configure the update, timeout, suppress, and garbage-collect timers as 5 seconds, 15 seconds, 15 seconds, and 30 seconds.

<Sysname> system-view
[Sysname] ripng 1
[Sysname-ripng-1] timers update 5 timeout 15 suppress 15 garbage-collect 30