bfd multi-hop min-transmit-interval

Use bfd multi-hop min-transmit-interval to configure the minimum interval for transmitting multi-hop BFD control packets.

Use undo bfd multi-hop min-transmit-interval to restore the default.

Syntax

bfd multi-hop min-transmit-interval value

undo bfd multi-hop min-transmit-interval

Default

The minimum interval for transmitting multi-hop BFD control packets is 400 milliseconds.

Views

System view

Predefined user roles

network-admin

mdc-admin

Parameters

value: Specifies the minimum interval for transmitting multi-hop BFD control packets, in milliseconds. The value range for this argument is 10 to 1000.

Usage guidelines

Use this command to make sure that the BFD packet sending rate does not exceed the device capability. The actual BFD control packet transmitting interval on the local end is the greater value between the minimum interval for transmitting BFD control packets on the local end and the minimum interval for receiving BFD control packets on the peer end.

Examples

# Configure the minimum interval for transmitting multi-hop BFD control packets as 500 milliseconds.

<Sysname> system-view
[Sysname] bfd multi-hop min-transmit-interval 500