bfd multi-hop detect-multiplier

Use bfd multi-hop detect-multiplier to configure the multi-hop detection time multiplier.

Use undo bfd multi-hop detect-multiplier to restore the default.

Syntax

bfd multi-hop detect-multiplier value

undo bfd multi-hop detect-multiplier

Default

The multi-hop detection time multiplier is 5.

Views

System view

Predefined user roles

network-admin

mdc-admin

Parameters

value: Specifies the multi-hop detection time multiplier in the range of 3 to 50.

Usage guidelines

The detection time multiplier determines the maximum number of concurrent BFD control packets that can be discarded.

Table 25: Detection interval calculation method

Mode

Detection interval

Control packet mode BFD session in asynchronous mode

Detection time multiplier of the receiver × actual packet sending interval of the receiver

Control packet mode BFD session in demand mode

Detection time multiplier of the sender × actual packet sending interval of the sender

Examples

# Configure the multi-hop detection time multiplier as 6.

<Sysname> system-view
[Sysname] bfd multi-hop detect-multiplier 6