Verifying transceiver modules

You can verify the genuineness of a transceiver module in the following ways:

To verify transceiver modules, execute the following command in any view:

Task

Command

Display key parameters of the transceiver in a specified interface

display transceiver interface [ interface-type interface-number ]

Display part of the electrical label information of transceiver in a specified interface

display transceiver manuinfo interface [ interface-type interface-number ]

# Display the main parameters of the transceiver plugged in interface GigabitEthernet 3/0/3.

<Sysname> display transceiver interface gigabitethernet 3/0/3
GigabitEthernet3/0/3 transceiver information:
  Transceiver Type              : 1000_BASE_SX_SFP
  Connector Type                : LC
  Wavelength(nm)                : 850
  Transfer Distance(m)          : 550(50um),270(62.5um)
  Digital Diagnostic Monitoring : YES
  Vendor Name                   : HP
  Ordering Name                 : JD118B

Table 20: Command output

Field

Description

Connector Type

Type of the connectors of the transceiver:

  • SC—Fiber connector, developed by NTT

  • LC—1.25 mm/RJ-45 optical connector developed by Lucent.

  • RJ-45

  • CX 4

Wavelength(nm)

  • Fiber transceiver—Central wavelength (in nm) of the laser sent. If the transceiver supports multiple wavelengths, every two wavelength values are separated by a comma.

  • Copper cable—Displayed as N/A.

Transfer distance(xx)

Transfer distance, where "xx" represents the distance unit: km (kilometers) for single-mode transceivers and m (meters) for other transceivers.

If the transceiver supports multiple transfer medium, every two values of the transfer distance are separated by a comma. The transfer medium is included in the bracket following the transfer distance value. The following are the transfer media:

  • 9 um—9/125 µm single-mode optical fiber

  • 50 um—50/125 µm multi-mode optical fiber

  • 62.5 um—62.5/125 µm multi-mode optical fiber

  • TP—Twisted pair

  • CX4—CX4 cable

Digital Diagnostic Monitoring

Support for the digital diagnosis function:

  • YES—Supported

  • NO—Not supported

Ordering Name

Product code.

# Display the electrical label information about the transceiver plugged in interface GigabitEthernet 3/0/4.

<Sysname> display transceiver manuinfo interface gigabitethernet 3/0/4
GigabitEthernet3/0/4 transceiver manufacture information:
  Manu. Serial Number  : MY13D41001
  Manufacturing Date   : 2014-01-20
  Vendor Name          : HP

Table 21: Command output

Field

Description

Manu. Serial Number

Serial number generated during commissioning and testing of the transceiver module.

Manufacturing Date

Commissioning date.