Displaying alarms present on your switch
Use the display alarm command to display the alarming information about your switch.
In standalone mode:
<Sysname> display alarm Slot Level Info 6 ERROR Fan 2 is absent. 6 ERROR Power 2 is absent. 6 ERROR The board in slot 10 is faulty. 3 WARNING The temperature of sensor 3 exceeds the lower limit.
Table 17: Command output
Field | Description |
---|---|
Slot | Slot number of the alarmed card. If the value is a hyphen (-), the alarm is generated by the chassis. |
Level | Alarm severity. Possible values include ERROR, WARNING, NOTICE, and INFO, In the descending order. |
Info | Detailed alarm information. |
faulty | The card is starting up or faulty. |
In IRF mode:
<Sysname> display alarm Chassis Slot Level Info 1 6 ERROR Fan 2 is absent. 1 6 ERROR Power 2 is absent. 1 6 ERROR The board in slot 10 is faulty. 2 3 WARNING The temperature of sensor 3 exceeds the lower limit.
Table 18: Command output
Field | Description |
---|---|
Chassis | ID of the IRF member switch with an alarm. If the value is a hyphen (-), the alarm was generated by the chassis. |
Slot | Number of the slot where the card resides. |
Level | Alarm severity. Possible values include ERROR, WARNING, NOTICE, and INFO, in descending order. |
Info | Detailed alarm information. |
The board in slot n is faulty. | The card in slot n is starting up or faulty. |