Configuring a location type affinity
The following location types are available:
current—Current location of the active process, which can be displayed with the display placement program command.
paired—Locations of standby processes.
primary—Master device.
To configure a location type affinity:
Step | Command | Remarks |
---|---|---|
1. Enter system view. | system-view | N/A |
2. Enter placement process view. |
| Settings in default placement process view take effect for all processes. Settings in placement process view take effect only for the specified process. |
3. Set the location type affinity. | affinity location-type { current | paired | primary } { attract strength | repulse strength | default | none } | By default, no location type affinity is set. |