Configuring other parameters
Step | Command | Remarks |
---|---|---|
1. Enter system view. | system-view | N/A |
2. Enter E1 interface view. | controller e1 number | N/A |
3. Configure a description. | description text | The default is interface name Interface. |
4. Configure the framing format. | frame-format { crc4 | no-crc4 } | The default is no-crc4. |
5. Set the line coding format. | code { ami | hdb3 } | The default is hdb3. |
6. Set the cable type. | cable { long | short } | The default is long. |
7. Configure the link idle code type. | idle-code { 7e | ff } | The default is 0x7E. |
8. Set the interframe filling tag type. | itf type { 7e | ff } | The default is 0x7E. |
9. (Optional.) Enable loopback and set the loopback mode. | loopback { local | payload | remote } | By default, loopback is disabled. |
10. Restore the default settings for the E1 interface. | default | N/A |
11. Shut down the E1 interface. | undo shutdown | By default, an E1 interface is up. |