Configuring AMD parameters

The accuracy of AMD detection results depends on the settings of detection parameters. You can increase the accuracy of the detection by adjusting AMD parameters.

To configure AMD parameters:

Step

Command

Remarks

1. Enter system view.

system-view

N/A

2. Enter voice view.

voice-setup

N/A

3. Configure AMD parameters.

amd parameter { machine-time value | max-analyze-time value | min-silence-time value | valid-voice-time value | voice-energy-threshold value }

Optional.

By default, the machine-time keyword is 2600 milliseconds, the max-analyze-time keyword is 4000 milliseconds, the min-silence-time keyword is 800 milliseconds, the valid-voice-time keyword is 120 milliseconds, the voice-energy-threshold keyword is 100.

For more information about the parameters, see HPE FlexNetwork MSR Router Series Comware 5 Voice Command Reference.


[NOTE: ]

NOTE:

The execution of the amd parameter command in voice view is a global configuration, which means it will be effective for the entire device.