Configuring the time adjustment function
Step | Command | Remarks |
---|---|---|
1. Enter system view. | system-view | N/A |
2. Enter E1/T1 interface view. | controller { e1 | t1 } slot-number | N/A |
3. Create a TS set for digital E&M signaling and select a start mode. | timeslot-set ts-set-number timeslot-list timeslots-list signal { e&m-delay | e&m-immediate | e&m-wink } | N/A |
4. Exit E1/T1 interface view. | quit | N/A |
5. Enter digital E&M voice subscriber line view. | subscriber-line slot-number:ts-set-number | N/A |
6. Configure the maximum interval between any two digits of a dialed number. | timer dial-interval seconds | Optional. The default is 10 seconds. |
7. Configure the maximum time the calling party waits for a ringback response. | timer ring-back seconds | Optional. The default is 60 seconds. |
8. Configure the maximum time the called party waits for the first digit. | timer wait-digit { seconds | infinity } | Optional. The default is 5 seconds. |