Configuring a start mode

Similar to analog E&M signaling, digital E&M signaling also provides three start modes: immediate-start, wink-start and delay-start. The time sequence of digital E&M signaling is the same as that of analog E&M signaling for all three start modes. The only difference is that analog E&M signaling transmits signaling information through the level change of Tip and Ring line but digital E&M signaling adopts 4 bits of TS16 to transmit signaling information in the same way as R2 signaling.

To configure the immediate start mode:

Step

Command

Remarks

1. Enter system view.

system-view

N/A

2. Enter E1/T1 interface view.

controller { e1 | t1 } slot-number

N/A

3. Create a TS set for digital E&M signaling and select the immediate start mode.

timeslot-set ts-set-number timeslot-list timeslots-list signal e&m-immediate

N/A

4. Exit E1/T1 interface view.

quit

N/A

5. Enter digital E&M voice subscriber line view.

subscriber-line slot-numbe:ts-set-number

N/A

6. Configure the delay that the calling party must experience before sending DTMF digits in immediate start mode.

delay send-dtmf millseconds

Optional.

The default is 300 milliseconds.

For more information about the timer dial-interval, timer wait-digit, timer ring-back, and delay send-dtmf commands, see HPE FlexNetwork MSR Router Series Comware 5 Voice Command Reference.

To configure the delay start mode:

Step

Command

Remarks

1. Enter system view.

system-view

N/A

2. Enter E1/T1 interface view.

controller { e1 | t1 } slot-number

N/A

3. Create a TS set for digital E&M signaling and select the delay start mode.

timeslot-set ts-set-number timeslot-list timeslots-list signal e&m-delay

N/A

4. Exit E1/T1 interface view.

quit

N/A

5. Enter digital E&M voice subscriber line view.

subscriber-line slot-numbe:ts-set-number

N/A

6. Configure the maximum duration of delay signal in delay start mode.

delay hold millseconds

Optional.

The default is 400 milliseconds.

7. Configure the delay that the called party must wait before sending a delay signal after it detects a seizure signal.

delay rising millseconds

Optional.

The default is 300 milliseconds.

To configure the wink start mode:

Step

Command

Remarks

1. Enter system view.

system-view

N/A

2. Enter E1/T1 interface view.

controller { e1 | t1 } slot-number

N/A

3. Create a TS set for digital E&M signaling and select the immediate start mode.

timeslot-set ts-set-number timeslot-list timeslots-list signal e&m-wink

N/A

4. Exit E1/T1 interface view.

quit

N/A

5. Enter digital E&M voice subscriber line view.

subscriber-line slot-numbe:ts-set-number

N/A

6. Configure the maximum time the calling party waits for wink signal after sending the seizure signal in wink start mode.

delay wink-rising millseconds

Optional.

The default is 2,000 milliseconds.

7. Configure the maximum duration of the wink signal sent by the called party in wink start mode.

delay wink-hold millseconds

Optional.

The default is 500 milliseconds.

8. Configure the minimum delay the called party must wait before sending a wink signal in wink-start mode.

delay send-wink millseconds

Optional.

The default is 200 milliseconds.