Configuring R2 interregister signaling

Step

Command

Remarks

1. Enter system view.

system-view

N/A

2. Enter E1/T1 interface view.

controller { e1 | t1 } slot-number

N/A

3. Create a TS set and enable R2 signaling for it.

timeslot-set ts-set-number timeslot-list timeslots-list signal r2

N/A

4. Enter R2 CAS view.

cas ts-set-number

N/A

5. Enable the terminating side to request calling party information.

ani { all | ka }

Optional.

Disabled by default.

6. Set the range for the number of calling number digits to be collected.

ani-collected min min-value max max-value

Optional.

By default, no restriction is placed on the number of calling number digits to be collected.

7. Configure the number of digits that should be collected to request a calling party flag.

ani-offset number

Optional.

The default for the number argument is 1.

8. Set the interdigit timeout time in interregister signaling.

ani-timeout timer-length

Optional.

3 seconds by default.

9. Adopt Group B signals to complete interregister signaling exchange.

group-b enable

Optional.

Group B signals are used by default.

10. Enable this end to send a number terminator to the terminating side.

final-callednum enable

Optional.

Disabled by default.

11. Configure the special characters that are supported during interregister signaling exchange.

special-character character number

Optional.

No special character is configured by default.

12. Configure register signal values in R2 signaling.

register-value { billingcategory | callcreate-in-groupa | callingcategory | congestion | demand-refused | digit-end | nullnum | req-billingcategory | req-callednum-and-switchgroupa | req-callingcategory | req- currentcallednum-in-groupc | req-currentdigit | req- firstcallednum-in-groupc | req-firstcallingnum | req-firstdigit | req-lastfirstdigit | req-lastseconddigit | req-lastthirddigit | req-nextcallednum | req-nextcallingnum | req-switch-groupb | subscriber-abnormal |subscriber-busy | subscriber-charge |subscriber-idle } value

Optional.

The defaults vary by country mode.

13. Configure the duration of register pulse signals such as A-3, A-4, and A-6 in R2 signaling.

timer register-pulse persistence time

Optional.

The default is 150 milliseconds.

14. Configure the maximum time waiting for a Group B signal.

timer register-complete group-b time

Optional.

The default is 30,000 milliseconds.