Configuring start mode
To configure the immediate start mode:
Step | Command | Remarks |
---|---|---|
1. Enter system view. | system-view | N/A |
2. Enter voice subscriber line view. | subscriber-line line-number | N/A |
3. Configure the immediate start mode for the E&M voice subscriber line. | em-signal immediate | The default is immediate start mode by default. |
4. Configure a delay before the originating side sends DTMF signals in the immediate start mode. | delay send-dtmf milliseconds | Optional. The default is 300 milliseconds. |
To configure the delay start mode:
Step | Command | Remarks |
---|---|---|
1. Enter system view. | system-view | N/A |
2. Enter voice subscriber line view. | subscriber-line line-number | N/A |
3. Configure the delay start mode for the E&M voice subscriber line. | em-signal delay | N/A |
4. Configure the delay signal duration in the delay start mode. | delay hold milliseconds | Optional. The default is 400 milliseconds. |
5. Configure the delay time from when the terminating side detects a seizure signal to when it sends a delay signal in the delay start mode. | delay rising milliseconds | Optional. The default is 300 milliseconds. |
To configure the wink start mode:
Step | Command | Remarks |
---|---|---|
1. Enter system view. | system-view | N/A |
2. Enter voice subscriber line view. | subscriber-line line-number | N/A |
3. Configure the wink start mode for the E&M voice subscriber line. | em-signal wink | The default is immediate start mode. |
4. Configure the delay time from when the terminating side receives a seizure signal to when it sends a wink signal in the wink start mode. | delay send-wink milliseconds | Optional. The default is 200 milliseconds. |
5. Configure the maximum amount of time the originating side waits for a wink signal after sending a seizure signal in the wink start mode. | delay wink-rising milliseconds | Optional. The default is 2,000 milliseconds. |
6. Configure the duration of a wink signal sent by the terminating side in the wink start mode. | delay wink-hold milliseconds | Optional. The default is 500 milliseconds. |