Enabling DLSw forwarding on an SDLC interface

With DLSw forwarding enabled on the SDLC interface, all local SNA devices connected to the interface will be able to communicate with the remote device through DLSw.

To enable DLSw forwarding on an SDLC interface:

Step

Command

Remarks

1. Enter system view.

system-view

N/A

2. Enter interface view.

interface interface-type interface-number

N/A

3. Enable DLSw forwarding on the interface.

sdlc enable dlsw

Disabled by default.